② :Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 5”Natural Gas W.C, and 10”L.P. Gas W.C. The external thread of product’s intake-tube is 3/4 inches.
Nozzle No. and Per BTU B.T.U./h Griddle Model C-RO4 C-RO-24G Gas Species and Intake manifold Hot pressure plates (in.W.C.7 8 1 8 3 8 C-RO4-12GR 3 8 1 2 7 8 3 8 C-RO6 3 8 1 2 4.
-8- 7 8 1 8 3 8 C-RO2-24GR 3 8 1 2 7 8 1 8 3 8 1 2 C-RO4-12GL 3 8 1 2 1 4 7 8 1 4 7 8 1 2
-9- 7 8 1 8 3 8 1 2 C-RO-36G 3 8 1 2 7 8 1 8 3 8 C-RO2-24GL 3 8 1 2 1 4 7 8 1 2 1 4 7 8
①:Size and package parameter information < Table 3> Model Overall Packing Oven dimensions(IN) size(IN) dimensions(IN) L x W x H LxWxH L x W x H C-RO6 38 C-RO4-12GR C-RO4-12GL C-RO2-24GR C-RO2-24GL 3 8 36*31*57 5 8 *41 *41 C-RO-36G 3 8 3 8 Griddle Number working of area(IN) oven L x W none 1 5 8 1 5 8 1 5 8 1 12*20 1 *26*14 2 26 24*20 36*20 ② Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 5”Natural Gas W.C, and 10”L.P. Gas W.C.
C-RO4-12GR C-RO4-12GL C-RO2-24GR C-RO2-24GL C-RO-36G Natural Gas 5 Propane 10 Natural Gas 5 Propane 10 Natural Gas 5 Propane 10 NG45 NG42 NG45 NG39 25,000 27,000 21000 27,000 LP54 23,000 NG45 25,000 LP54 23,000 NG45 25,000 LP54 23,000 LP52 27,000 NG42 27,000 LP52 27,000 NG42 27,000 LP52 27,000 LP54 21000 NG45 21000 LP54 21000 NG45 21000 LP54 21000 LP52 27,000 NG39 27,000 LP52 27,000 NG39 27,000 LP52 27,000 148,000 4 1 1 140,000 125,000 2 1 1 1 121,000 102,000 2 1 1 102,000 4.
- 12 - 3 8 1 2 C-RO6-12GL 7 8 3 8 1 2 7 8 1 8 3 8 C-RO6-12GR 3 8 1 2 1 4 7 8 1 2 1 4 7 8 1 8
- 13 - 1 8 3 8 1 2 C-RO4-24GL 7 8 3 8 1 2 7 8 1 8 3 8 C-RO4-24GR 3 8 1 2 7 8 1 4 1 2 7 8 1 4
- 14 - 1 8 3 8 1 2 C-RO2-36GL 7 8 3 8 1 2 7 8 1 8 3 8 C-RO2-36GR 3 8 1 2 1 4 7 8 1 2 1 4 7 8
① Size and package parameter information Model Overall Packing Oven dimensions(IN) size(IN) dimensions(IN) L x W x H LxWxH L x W x H C-RO8 5 8 C-RO6-12GR C-RO6-12GL C-RO4-24GR C-RO4-24GL C-RO2-36GR C-RO2-36GL 50 3 8 48*31*57 3 8 *41 3 8 *41 Griddle Number working of area(IN) oven L x W none 2 5 8 2 5 8 2 5 8 2 12*20 20*26*14 24*20 36*20 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 5”Natural Gas W.C, and 10”L.P. Gas W.C.
C-RO4-24GR C-RO4-24GL C-RO2-36GR C-RO2-36GL Natural Gas 5 Propane 10 Natural Gas 5 Propane 10 NG45 25,000 LP54 23,000 NG45 25,000 LP54 23,000 NG42 27,000 LP52 27,000 NG42 27,000 LP52 27,000 NG45 21000 LP54 21000 NG45 21000 LP54 21000 NG44 24,000 LP53 24,000 NG44 24,000 LP53 24,000 196,000 4 1 1 2 188,000 173,000 2 2 1 2 169,000 4.
- 17 - 3 8 1 2 C-RO8-12GL 7 8 3 8 1 2 7 8 1 8 3 8 C-RO8-12GR 3 8 1 2 7 8 1 4 1 2 1 4 7 8 1 8
- 18 - 3 8 1 2 C-RO6-24GL 7 8 3 8 1 2 178 1 8 3 8 C-RO6-24GR 3 8 1 2 7 8 1 4 112 1 4 7 8 1 8
- 19 - 1 8 3 8 1 2 C-RO4-36GL 7 8 3 8 1 2 7 8 1 8 3 8 C-RO4-36GR 3 8 1 2 7 8 1 4 1 2 7 8 1 4
- 20 - 3 8 1 2 C-RO2-48GL 7 8 3 8 1 2 7 8 1 8 3 8 C-RO2-48GR 3 8 1 2 1 4 7 8 1 2 1 4 7 8 1 8
①:Size and package parameter information Overall Packing Oven dimensions(IN size(IN) dimensions(IN) ) L x W x H LxWxH L x W x H Model C-RO10 C-RO8-12GR C-RO8-12GL C-RO6-24GR C-RO6-24GL C-RO4-36GR C-RO4-36GL C-RO2-48GR C-RO2-48GL 5 62 8 3 60*31*57 8 3 *41 8 3 *41 8 Griddle Number working of area(IN) oven L x W none 2 5 8 2 5 8 2 5 8 2 5 8 2 12*20 1 26 *26*14 2 24*20 36*20 48*20 ② Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 5”
Nozzle No. and Per BTU B.T.U/h Griddle Model C-RO10 C-RO8-12GR C-RO8-12GL C-RO6-24GR C-RO6-24GL C-RO4-36GR C-RO4-36GL C-RO2-48GR C-RO2-48GL Gas Species and Intake manifold Hot pressure plates (in.W.C.
6. Installation and Debugging Any erroneous installation, adjustment, refit, overhaul or maintenance may cause property damage or personal injury. The work shall be performed by authorized and licensed technicians, otherwise the manufacturer has the right not to provide warranty service; Only be installed in accordance with the local code. If no similar standard, you should conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas Installation Code, CSA-B149.1, or the L.P.
same level with other series of the same stove; Please lift the equipment rather than drag if you need to move it; Please refer to P16“11. Schematic Diagram for Installation of Rear Panel” for the installation methods of rear panel. Supplied gas pressure regulator is factory set at 5”Natural Gas W.C, and 10”L.P. Gas W.
joint screw arbor, to prevent gas escape! 6.2 Debugging It’s very important to debug the new stove. Through the comprehensive system test of equipment, we can ensure function and safety performance of products. Discovering any potential problems before use (such as equipment’s placement, ventilation, operation, etc), can avoid costly losses. 7. Safety Notices and Precautions Warning! For your safety, do not place petrol and other flammables nearby. Please keep clean and free of flammables surroundings.
used for other purposes; The equipment does not contain any user-serviceable parts. Dealers or technicians will repair it. Do not take apart any spare parts without authorization; Never change any other parts without authorization to this equipment, otherwise, may cause hazards, and the manufacturer has the right not to provide warranty service; Steel cutting producers used to manufacture with sharp edges.
Figure 2 Figure 3 Figure 4 Figure 5 8.3 Lighting of normally open fire of stove 1. Align the OFF indicative line of thermostat valve knob to the arrow (Figure 5) to close the valve. 2. Open the underside face plate of oven (figure 6), thoroughly press the button at the front end of safety valve, and ignite the pilot fire by lighter with another hand simultaneously (figure 7 and figure 8). Do not loosen the button immediately after the pilot gas is ignited. Down-press it for 10 – 15 seconds.
Figure 6 Figure 8 Figure 7 Figure 9 Figure 10 8.4 Ignition of main fire of oven After the normally fire was ignited, the main fire valve of safety valve was opened, and press the thermostat valve knob to rotate to the position LOW counterclockwise (figure 9). At this moment, the oven burner is ignited. Rotate the thermostat valve knob counterclockwise continuously to the required temperature (figure 10) and the oven starts warming.
8.6 Stove Operation Before using the stove for the first time, please use a mild detergent to wipe it clean. Do not use corrosive or abrasives detergent. Turn the burners on about 15-20 minutes before broiling for preheating, according to the cooking requirement to adjust the flame size. Notice: When first preheating, the furnace will smoke above.
angle. Then, tighten the fastening screw bolt of damper to guarantee the appliance does not get loose. At last, reinstall the underside face plate of oven. ④Caution: Each burner damper has been adjusted before delivery (once air input), Normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians. 9.
Recommended cleaning methods Items Body Methods Wipe it with a soft cloth and mild detergent; Times daily Turn off valves when not in use; Control panel Wipe panel and control valve knob with daily mild detergent. Pull out catch tray from front body until the equipment cools down. Use a cloth with cleaning agent to wipe unit Catch tray surface, wipe up residue. Reinstall Per use after cleaning.
10. Troubleshooting
Problems Not lighting Ignite the pilot light but not the main fire Possible causes 1.Insufficient gas pressure in pipe 2.Nozzle occlusion 1.Insufficient gas pressure in pipe 2.The main fire nozzle occlusion 3.Gas control valves have problems 4.The pilot light and the main fire’s distance is too far Problem solving 1.Contact the local gas supply dept. 2.Dredge nozzle 1.Contact the local gas supply dept. 2.Dredge nozzle 3.Change gas control valves 4.Note 1、Pressure maintaining valve connects with air intake, must be installed by authorized and licensed technicians, to ensure interface tightness. 2、The pressure regulator(s) have connected, the maximum load of natural gas cannot exceed 6”, and of LP cannot exceed 12”. 3、Adjustment range of the pressure regulator(s) is 3”-6”for natural gas, and 5”-12”for L.P.. 11.
Step III (Fasten the rear top plate at the corresponding position of rear panel) Step V ( Insert the assembled rear top plate into the corresponding position of stove body) Migali Industries, Trusted Since Step IV (Fix the rear top plate with rear panel by hexagon bolt) Step VI (Fix the assembled rear panel with the stove body by self-tapping screw) Inc. 1955 516 Lansdowne Ave Camden, NJ 08104 Service Call: 800.852.5292 Service Email: warranty@mgiali.