RED to POSITIVE
BLACK to NEGA
TIVE
Battery Harnes
s
Connector
0
2
50 Foot
Power Cable
run through PVC
10 Foot
Po
wer Cable
Battery Harness
Connector
0
2
Bottom
Access Panel
O
N
O
F
F
ON/OFF
Switch
CONNECTING THE POWER CABLES:
1. Connect the red wire from the 50 foot and the 10 foot power cable to the POSITIVE (+)
terminal of the battery.
2. Connect the black wire from the 50 foot and the 10 foot power cable to the NEGATIVE (-)
terminal of the battery.
3. Plug the other ends (with the plug) of the power cables to the operator battery connectors.
One at each operator.
1
1. Place both operators in the upside down position.
2. Make sure the power switch is in the OFF position and remove the control board access covers.
ON/OFF
POSITION THE OPENERS:
2
O
N
/
O
FF
Battery Harness
Connector
Po
wer Cable
from Battery