Troubleshooting Guide
If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department.
Audible Feedback
Symptom Diagnosis Check:
1 short beep upon
activation
Blown Fuse
Low or Bad Battery
Loose Battery Connection
•Fuse
•BatteryUnderLoad
•BatteryHarnessConnections
1 short beep upon
power up
Circuit Board Powered
Up & Ready
•NormalOperation
Continuous
Uninterrupted Alarm
Circuit Board Senses an
Obstruction
•PathofGate
•GateforLevelandPlumb
•StallForceAdjustment
•DisconnectSafetyDevices
•RevCounter
1 beep with 10 seconds
off
Low Battery Condition •Fuses
•BatteryHarnessConnections
•BatteryUnderLoad
1 beep then 2 beeps Master Motor Terminals
Shorted
• ConnectionstoMasterInputs
• MasterArmPowerCable
• Motor
• CircuitBoard
1 beep then 3 beeps Slave Motor Terminals
Shorted
• ConnectionstoMasterInputs
• MasterArmPowerCable
• Motor
• CircuitBoard
1 beep with 2 seconds
off
Master Arm Limit Switch
Error
• ConnectionstoMasterInputs
• MasterArmPowerCable
• MasterInputORG&GRN,BRN&GRNvoltagewith
wires disconnected. 11VDC across each terminal.
2 beeps with 2 seconds
off
Slave Arm Limit Switch
Error
• ConnectionstoSlaveInputs
• SlaveArmPowerCable
• SlaveInputORG&GRN,BRN&GRNvoltagewith
wires disconnected. 11VDC each across each terminal.
3 beeps with 2 seconds
off
Master Arm Rev Counter
Error
• ConnectionstoMasterInputs
• MasterArmPowerCable
• RevCounter
4 beeps with 2 seconds
off
Slave Arm Rev Counter
Error
• ConnectionstoMasterInputs
• MasterArmPowerCable
• RevCounter