Owner manual
35
Visual Feedback
Symptom
Diagnosis Check:
Status (clear)
1 blink
Cycle Terminal
Shorted
Disconnect the push button, keypad, intercom keypad, or any other
accessory wired to this terminal. Try the remote. If the remote works, then
the problem is the accessory.
Status (clear)
2 blinks
Safety Terminal
Shorted
Disconnect the loop detector, photo beam, or any other accessory wired
to this terminal. Try the remote. If the remote works, the problem is the
accessory.
Status (clear)
3 blinks
Exit Terminal
Shorted
Disconnect exit wand, loop detector, photo beam, Knox box, or any other
accessory wired to this terminal. Try remote. If the remote works, the
problem is the accessory.
Status (clear)
4 blinks
Shadow Terminal
Shorted
Disconnect the loop detector, photo beam, or any other accessory wired to
this terminal. Try remote. If the remote works, the problem is the accessory.
Status (clear)
5 blinks
Close Edge Terminal
Shorted
Disconnect the edge sensor, photo beam, or any other accessory wired to this
terminal. Try the remote. If the remote works, the problem is the accessory.
Status (clear)
6 blink
Open Edge Terminal
Shorted
Disconnect edge sensor, photo beam, or any other accessory wired to this
terminal. Try the remote. If the remote works, the problem is the accessory.
RF (yellow) Flickers Receiving318MHz
RF
Normal operation when remote or wireless keypad is used.
RF (yellow) OFF No318MHzRF
Received
• BatteryinRemote
• ProgramRemote
• AntennaReceiverConnections
• AntennaReceiver
Power (green) ON AC or Solar Power
Present
Normal Operation
Power (green) OFF No AC or Solar
Power
Transformer:
• BreakerorGFI
• PoweratACoutlet.
• OutputofTransformer.
• Voltageonwireat18VACInput
Solar:
• SolarPanelWiresReversed
• Weather
• SolarPanelPlacement
• OutputofSolarPanel
• VoltageonwireatSolarInput
Charge (red) ON Fast Charging Mode Battery Voltage should be ~14.8 VDC when connected to the circuit board
Charge (red) Fast
Blinking
Soak Charging Mode Battery Voltage should be ~14.1 VDC when connected to the circuit board
Charge (red) Slow
Blinking
Float Charge Battery Voltage should be ~13.8 VDC when connected to the circuit board
Charge (red) OFF Battery Not Being
Charged
•ACpower
•Transformer
•SolarPanel
•ChargingCircuit