Product Manual B

MM-LPS13 Installation Manual 5
rev 05.16.13
GATE OPERATOR INSTALLATION
Gate Preparation
Overview of Operator Installation
Level
Plumb
Concrete
Concrete
Be sure the gate is properly installed and slides smoothly before installing the MM-LPS13 Slide Gate Operator.
Thegatemustbeplumb,level,andmovefreely.Thegatemustnotbindordragontheground.Never
use a wheel on the gate, because the additional drag and resistance can cause the operator to obstruct.
The diagram below shows a single slide gate installation with required safety features. The operator
must be installed on the inside of the gate. Mighty Mule requires using safety edges and roller guards
to help reduce the possibility of bodily injury.
Chain
Contact Sensor
Roller Guard
Receiver
(cable in separate
conduit)
Roller Guard
Contact Sensor
Contact Sensor
(REQUIRED - not included)
(REQUIRED - not included)
(REQUIRED - not included)
(REQUIRED - not included)
(REQUIRED - not included)
Use PVC Conduit
(not included)
Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).
120 Volt Indoor
Transformer
(Surge Protector
not supplied)
Roller Guard
(REQUIRED - not included)
Chain Bracket
Chain Bracket
for power cables.
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
Operator
Photo Beam
Photo Beam