Product Manual B

MM-LPS13 Installation Manual 19
rev 05.16.13
INPUT CONNECTIONS
FIRST OPERATOR ACCESSORY
RED
BLK
ORG
BLU
GRN
CLS EDG
OPN EDG
BLU
ORG
WHT
GRN
5
3
2
1
4
All inputs are dry-contact, normally open.
CLS EDGE:
(Can be used with edge sensor device or photo beam)
•Activationofthisinputwhilethegateisclosingwillcause
the gate to stop and reverse direction for approximately 2
seconds. The autoclose will reset if the unit has returned to
the full open position.
•Activationofthisinputwhilegateisopeninghasnoeect
(gate will continue to open). Autoclose will reset (if enabled).
•Activationofthisinputwhilegateisidlewillpreventgate
from closing.
OPN EDGE:
(Can be used with edge sensor device or photo beam)
•Activationofthisinputwhilethegateisopeningwillcause
the gate to stop and reverse direction for approximately 2
seconds.
•Activationofthisinputwhilegateisclosinghasnoeect(gate
will continue to close).
•Activationofthisinputwhilegateisidlewillpreventgatefrom
opening.
ORG: (Typically used with photo beam devices, loop detectors
or other non-contact sensors)
•Activationofthisinputwhilethegateisclosingwillcausethe
gate to stop and return to the open position
•Activationofthisinputwhilegateisopeninghasnoeect
(gate will continue to open). Autoclose will reset (if enabled).
•Activationofthisinputwhilegateisidlewillpreventgatefrom
closing.
BLU: (Typically for use with exit loop or wand)
•Activationofthisinputwillopenthegateifit’snotalreadyat
the open position.
•Activationofthisinputwhilegateisattheopenlimitwill
restart the auto close time (if enabled).
WHT: (Typically used with push button or hard wired key pad)
•Eachactivationatthisinputwillcycletheoperationasfollows
... X Open X STOP X CLOSE X STOP X OPEN X ...
1
2
3
4
5