Product Manual

MM562 Installation Instructions 23
Step 5
Strip
3
/16" off the ends of the low voltage wire
and twist tightly. Attach these ends to the 18VAC
terminals located on the POWER IN terminal block
(see illustration at right). Be certain not to let the
exposed wires touch each other!
Insert one transformer wire into an 18VAC terminal.
Insert the other transformer wire into the remaining
18VAC terminal. The transformer wires can be
connected to the 18VAC terminals regardless of
polarity or color.
Tighten set screws against exposed end of wires.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
POWER
INPUT
LOCK
PWR
AUX
RLY
CONTROL
OUTPUTS
MASTER OPERATOR2ND OPERATOR
GTO 18VOLT
TRANSFORMER
OR SOLAR
GTO
LOCK
AUX
RED
BLACK
RED
BLACK
Low Voltage Wire
from AC Transformer
or Solar Panel
Power Cable
from Master Arm
Power Cable
from Slave Arm
PVC Pipe with
Low Voltage Wire
from Transformer
25
FUSE
BATT+
BATT-
1 2 3 4
ON DIP
STATUS
LEARN RMT
RECEIVER
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
ALM
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120MIN MAX
CHARGING
PWR IN
GTO RCVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
GTO
TRANSF
LOCK
PWR
AUX
RLY
POWER
INPUTS
CONTROL
OUTPUTS
MASTER CABLESLAVE CABLE
CONTROL INPUTS
AUTO CLOSE TIME STALL FORCE
CLOSE
EDGE
18 VAC
or
SOLAR
GTO
LOCK
AUX
WARNING! DO NOT PLUG THE TRANSFORMER
INTO AN OUTLET DURING THIS STEP! THE
TRANSFORMER MUST ONLY BE PLUGGED INTO
AN OUTLET DURING STEP 7!
Step 3
Lay the measured length of low voltage wire in a trench following a path
from the selected electrical outlet to the control box. Wires coming up from
the ground should be run through PVC conduit to protect them from lawn
mower blades, weed eaters, and grazing animals. Be sure to bury the wire
laid in the trench.
Step 4
Feed the low voltage wire upward
through the pre-drilled hole in the knock
out on the bottom of the control box.
Pull 6" to 8" of wire into the control
box, enough to reach the Power Input
on the control board.
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE
The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, PVC sheathed
wire. This particular gauge enables the transformer to provide an adequate charge through the control
board to the battery at distances up to 1000 ft.
DO NOT use telephone wire or solid core wire. Unlike stranded wire, these types of wire are not
appropiate for use with your gate opener system.
AVOID splicing wires together. Splicing permits corrosion and seriously degrades the wire's ability to
carry an adequate current.
Insert Low Voltage
Wire from Transformer