Specifications

Initial setup MC13xx Users Manual Rev. 1.08
5 Initial setup
The MC13xx is delivered with initial parameters and therefore does not need to be configured via the
serial link.
5.1 Serial number and firmware revision
Serial number and firmware revision is provided in MC13xx non volatile memory. Use :v command
(Read serial number and firmware revision
) to read serial number and firmware revision. The serial
number is also marked on the type plate of the camera.
5.2 PowerUpProfile
The PowerUpProfile is the contents of all camera registers to be loaded from non-volatile memory after
power up.
5.3 Camera Profile
The actual set of parameters is called Camera Profile. All changes of parameters by the serial link is
reflected in the Camera Profile. On command the Camera Profile is saved to 8 user profiles or one Pow-
erUpProfile. It is loaded from 8 user profiles or 8 factory profiles or the PowerUpProfile. The camera
profile is volatile and must be stored to the PowerUpProfile to be reactivated on next poer up.
5.4 Factory profile
The factory profile can be read but not written by the user.
5.5 User profiles
The user can store up to eight PowerUpProfiles in non volatile memory. All load or write commands
exchange data between the PowerUpProfile and one of the four user profiles.
Profil-Nr. Video data
width
resolution
/ Pixel
Image
frequency
/fps
0 2x8 100 x 100 4.852
1 2x8 240 x 240 1.011
2 2x8 640 x 480 202
3 2x8 1280 x 1024 47
4 2x10 640 x 480 150
5 2x10 1280 x 1024 33
6 8x8 1280 x 1024 120
7 8x8 640 x 480 954
Table 5-1
11