ToF Laser Distance Sensor Featuring LoRaWAN® EM400-TLD User Guide
Safety Precautions Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. The device must not be disassembled or remodeled in any way. In order to protect the security of the device, please change device password when first configuration. Default password is 123456.
Contents 1. Product Introduction ......................................................................................................................... 4 1.1 Overview ...................................................................................................................................4 1.2 Features ................................................................................................................................... 4 2. Hardware Introduction .....................................
1. Product Introduction 1.1 Overview EM400-TLD is a LoRaWAN® distance sensor based on ToF (time of flight), which is mainly used for detecting the fill level and position status. With an appropriate FOV with the maximum field angle of 27°, it has almost no blind spot when installed on small-sized waste bins or containers. The embedded temperature sensor enables it to monitor whether the containers are burning for security reasons.
2.2 Hardware Overview 2.3 Dimensions (mm) 2.4 Power Button EM400-TLD can be switched on/off via NFC. Besides, users can use power button to switch on/off and reset the device manually. Function Action LED Indication Switch On Press and hold the button for more than 3 seconds. Off → On Switch Off Press and hold the button for more than 3 seconds. On → Off Reset Press and hold the button for more than 10 seconds. Quickly Blinks Check On/Off Status Quickly press the power button.
3. Attach the smartphone with NFC area to the device to read the basic information. 4. Basic information and settings of devices will be shown on ToolBox if it’s recognized successfully. You can switch on/off, read and write the device by tapping the button on the App. In order to protect the security of devices, password validation is required when configuring via unused phone. Default password is 123456. Note: 1) Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
Parameters Device EUI App EUI Application Port Join Type Description Unique ID of the device which can also be found on the label. Default App EUI is 24E124C0002A0001. The port used for sending and receiving data, default port is 85. OTAA and ABP mode are available. Application Key Appkey for OTAA mode, default is 5572404C696E6B4C6F52613230313823. Device Address DevAddr for ABP mode, default is the 5th to 12th digits of SN.
LoRaWAN Frequency Settings: Go to Setting > LoRaWAN Settings to select supported frequency and select channels to send uplinks. Make sure the channels match the LoRaWAN® gateway. If frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas.
3.3 Basic Settings Go to Device > Setting > General Settings to change the reporting interval, etc. Parameters Device Mode Description Select from “Standard Mode” or “Bin Mode”. Reporting interval of transmitting data to network server. Reporting Interval Standard Mode: 10 minutes as default; Bin mode: 20 minutes as default. Enable or disable the installation height of the device when in Bin Mode. Note: Installation Height 1.
Parameters Collecting Interval Threshold Dismiss Report Description Collecting interval of ToF sensor to detect distance. The default value for standard mode is 10 minutes, for bin mode is 20 minutes. When the collected value changes from outside the threshold to within the threshold, a threshold dismiss packet will be reported. 3.5 Maintenance 3.5.1 Upgrade 1. Download firmware from Milesight website to your smartphone. 2.
3.5.2 Backup EM400-TLD support configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRaWAN® frequency band. 1. Go to Template page on the App and save current settings as a template. You can also edit the template file. 2. Select one template file which saved in the smartphone and click Write, then attach to another device to write configuration. Note: Slide the template item left to edit or delete the template.
area to device to complete reset. 4. Installation 1. Drill two holes on the container cover according to the location of device mounting holes. 2. Put the device under container cover and align the holes in order to perfectly screw the bolts into the holes from the other side of the cover. Besides, the device can also be fixed by two M4 mounting screws and wall plugs.
Installation Note: In order to provide the best data transmission, please ensure the device is within the signal range of the LoRaWAN® gateway and keep it away from metal objects and obstacles. Avoid strong light, like direct sunlight or IR LED, in the detection area. Do not install the device close to glass or mirror. After installation and adjustment, please remove the protective film. Do no touch the lens of sensor directly to avoid leaving the fingerprint on it.
0b (Power On) Device is on 0f (Device Type) 00: Class A, 01: Class B, 02: Class C 16 (Device SN) 16 digits Example: ff0bff ff0101 ff166329c42503920003 ff090100 ff0a0101 ff0f00 Channel Type Value Channel Type Value ff 0b (Power On) ff (Reserved) ff 01 (Protocol Version) 01 (V1) Channel Type Value Channel Type Value ff 16 (Device SN) 6329c42503 920003 ff 09 (Hardware version) 0100 (V1.0) Channel Type Value Channel Type Value ff 0a (Software version) 0101 (V1.
besides, it will also report a alarm dismiss packet if distance returns back to normal value. When the abrupt change of temperature is greater than 5 °C, it will report a temperature threshold packet.
71 (Set Device Mode) 00 = Standard Mode; 01 = Bin Mode 3e (Set Tilt & Distance Switch) 00 = Disable; 01 = Enable 56 (Set ToF Distance Sensor) 00 = Disable; 01 = Enable 9 Bytes, CTRL(1B)+Min(2B)+Max(2B)+00000000 (4 B) CTRL: Bit2~Bit0: 000-disable 001-below 010-above 06 (Set Threshold Alarm) 011-within 100-below or above Bit5~Bit3: 001-Standard Mode 010-Bin Mode Bit6=0 Bit7: 0 - disable threshold dismiss report 1 - enable threshold dismiss report Example: 1. Set reporting interval as 20 minutes.
4. When the distance is below 3mm or above 20mm, the sensor will send threshold alarm.