“Open window” function
The heater has an “open window” function that is activated instantly when it registers a
sudden drop in temperature with more than 2 degrees Celsius in 2 minutes. The heater
will automatically stop heating and FO will be visible in the display of the heater.
The heater will automatically start heating again aer 10 minutes (the display switch
from FO to desired room temperature).
Resetting the heater
Turn o the heater's main switch. Press and hold while you turn on the heater's
main switch.
Memory function
The heater remembers all the temperature settings and will automatically return to the
desired temperature aer a power cut. Your day- and nighttime setbacks will however
be deleted aer a power cut, and you will need to register the programs again.
See gure 5 on separate illustration sheet
TIPS! The thermostat can be used as a regular electronic thermostat (i.e. the
heater will maintain a constant temperature 24 hours a day). Please see the section
explaining usage without WiFi connection for further information
Control Panel
See gure 6 on separate illustration sheet
1. Display (shows the desired room temperature by default)
2. WiFi indicator
3. Power indicator — Shows whether the heater is using power or not
4. Control button (+) (increase temperature)
5. Control button (–) (reduce temperature)
6. WiFi button
7. Function button (F)
ATTENTION! In the event of a power cut, the thermostat will reconnect with WiFi
where all the temperatures are saved.
WARNING! BEFORE THE HEATER IS TURNED ON, IT MUST BE ATTACHED TO A WALL. IF
THE HEATER IS NOT INSTALLED CORRECTLY OR IS INSTALLED ASKEW, THIS MAY CAUSE
THE HEATER TO MALFUNCTION OR IN THE WORST CASE, BE DAMAGED.
If the temperature sensor is not functioning properly, you will see this
symbol on the display. Please contact the dealer or importer.