NSEQ-2 GENERAL SPECIFICATIONS
THD + Noise, 20 Hz - 30 kHz < .009%, typ .002 % (all EQ bands switched in)
Frequency Response -3 dB (SS) Sub 1 Hz to beyond 300 kHz
Frequency Response -3 dB (VT) Sub 2 Hz to beyond 200 kHz
Frequency Response, Stereo Deviation < .15 dB
Maximum Input Level, EQ Flat +28 dBu (VT), +24 dBu (SS)
Maximum Output Level +28 dBu (VT), +24 dBu (SS)
Input Impedance (SS) see user manual, page four
Input Impedance (VT) see user manual, page four
Output Impedance (SS) 55 ohms (transformerless)
Output Impedance (VT) 150 ohms (transformerless)
Recommended Load > 150 ohms (SS), > 3 k ohms (VT)
Noise (Boost/Cut switch @ 10 dB) -104 dBu (SS), -94 dBu (VT) (all EQ bands in)
Common Mode Rejection Ratio (bal opt.) > 50 dB, > 75 dB typical, 100mV, to 20 kHz
Slew Rate, +26 dBu out > 25 volts per microsecond
XLR Polarity Pin 2 positive polarity, Pin 1 = ground
EQUALIZER PARAMETERS
"Q" Range Q = 0.4 to 4.0, sweepable
Maximum Boost & Cut +/- 20 dB (21 step detent)
Minimum Boost & Cut +/- 10 dB (21 step detent)
Low Range Fixed Frequencies 20, 34, 56, 100, 180, 270 Hz
High Range Fixed Frequencies 4.8, 5.8, 8.0, 10, 16, 21 kHz
Low/High Range Fixed "Q" Q = 1.0
Low-Mid Parametric Sweep Frequencies 20 Hz to 220 Hz -or- 220 Hz to 2.5 kHz
High-Mid Parametric Sweep Frequencies 250 Hz to 2.5 kHz -or- 2.5 kHz to 25 kHz
Hardwire Bypass for Each Channel? Yes
Peak/Shelf Selection on Hi & Lo bands? Yes
Bypass Selection on Each Band? Yes
Twin Topology Selection Switch In = FET Amplifiers
Switch Out = Vacuum Tube Amplifiers
ELECTRO-MECHANICAL SPECIFICATIONS
Power Consumption 40 Watts, nominal
Power Requirements 100VAC to 240VAC, 50/60Hz, selectable
Fuses (2 required) 2 ea 1A with 100-120VAC mains (5x20mm,
slow-blow, 250V)
2 ea 500mA with 200-240V mains (5x20mm,
slow-blow, 250V)
Internal DC Power +350V, +25V, -25V, +12V
Dimensions 19" W x 12.5" D x 3.5" H
Net Weight approximately 24 pounds