User Manual

3- INSTALL RECEIVER
-Open box, remove lid from the MRF-01
receiver.
-Position receiver on operator, so that
its wiring will reach the operator
terminal strip. Keep in mind that the
Green antenna wire must be exposed to
the AW12-RF Transmitter/Air Wave™
Switch. It cannot be behind any type of
metal.
-Connect the Red (+) & Black (-) to your
24VAC/DC source. The White wire
connects to a low voltage COMMON
terminal. The Yellow wire connects to
your EDGE/SAFETY terminal.
4- PROGRAMMING
-Apply power to the receiver.
-Green Power LED stays on; Channel 1
Red LED will be blinking.
-To enter “Learn” mode simply press
your fingertip onto CH1 (in the LEARN
BUTTON section of the PCB). The Red
LED remains on and the Amber Learn
LED will begin to blink.
-Activate the edge & note the Red &
Amber LED’s will blink alternately
rapidly. Then the Red LED will go out &
the Amber LED remains on.
-Channel 1 is now programmed.
-To start-over/erase programming,
press and hold CH1 again for 3 seconds,
LED’s will blink for 5 seconds & then go
into fault mode.
5- TEST SAFETY EDGE
-Ensure that your door stops/reverses
when safety edge is activated during
close cycle.