Owner`s manual

OM-223 194 Page 10
3-4. Installing Gas Supply
Ref. ST-148 265-B / Ref. ST-149 827-B / Ref. ST-158 697-A
2
CO
2
Gas
1
Argon Gas
OR
3
Chain gas cylinder to running gear,
wall, or other stationary support so
cylinder cannot fall and break off
valve.
1 Regulator/Flow Gauge
Install so face is vertical.
2 Gas Hose Connection
3 Flow Adjust
Typical flow rate is 20 cfh (cubic
feet per hour). Check wire man-
ufacturer’s recommended flow
rate. This flow gauge can be
adjusted between 5 and 25 cfh.
3-5. Installing Wire Spool and Adjusting Hub Tension
ST-072573-B
When a slight force is needed to turn spool, tension is set.
15/16 in
Tools Needed: