3-6. Positoning Jumper Links (230/400V 3-Phase Models)
230 V
400 V
3-7. Electrical Service Guide
Migmatic Model
271 273 333 383
Input Voltage
230 230 400 230 400 230 400
Input Amperes at Rated Output
35 23 13 32 19 38 22
Max Recommended Standard Fuse or Circuit
Breaker Rating in Amperes
35 23 13 32 19 38 22
** Input Conductor Size in mm
2
4 2.5 2.5 6 4 6 4
** Grounding Conductor Size in mm
2
4 2.5 2.5 6 4 6 4
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters.
Consult national and local regulations.