Owner`s manual

OM-236 948 Page 18
4-3. Volt-Ampere Curves
237 466 / 237 468 / 237 470
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
C. TIG Mode
0 100 200 300 400 500 600
0
10
20
30
40
50
60
70
80
90
100
DC Volts
DC Amperes
Min
Max
0 100 200 300 400 500 600
DC Amperes
0
10
20
30
40
50
60
70
80
90
100
DC Volts
0 100 200 300 400 500
DC Amperes
0
10
20
30
40
50
60
70
80
90
100
DC Volts
Min
Max