Owner's Manual Welding Engine Driven Welding Generator Big Blue 400P,Big Blue 500 X

OM-4421 Page 38
9-2. Routine Maintenance
Stop engine before maintaining.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
= Check = Change = Clean = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
FUEL
WATER
Section 5-7,
9-7
Fuel/Water Separator Fuel Level Oil Level Oil, Fuel Spills
Coolant Level
Every
50
Hours
Weld Terminals
Every
100
Hours
Section 9-4
Battery Terminals Air Cleaner Hoses Air Cleaner Element
Every
250
Hours
1/2 in.
(13 mm)
Engine
Manual,
Section 9-5
Unreadable Labels Fan Belt Tension Oil Oil Filter Spark Arrestor
Every
500
Hours
 Weld Cables
Every
1000
Hours
OR
SLUDGE
FUEL
Section 9-7,
9-3 and En-
gine Manual
Radiator Fluid Level And
Thermosstat
Inside Unit FuelFilter Drain Sludge
 Slip Rings*
 Brushes*
Valve Clearance*
Every
2000
Hours
Injectors*