Portable Generator User Manual

OM-4417 Page 12
Continuous Welding
4-5. Duty Cycle
220 625A
Duty cycle is the percentage of 10
minutes that unit can weld at rated
load without overheating.
Exceeding duty cycle can
damage unit and void
warranty.
100% Duty Cycle at 80 Amperes CC/DC
20% Duty Cycle at 145 Amperes CC/DC
% DUTY CYCLE
WELD AMPERES
0
0
10 20
20
30 40
40
50
60
60 70 80
80
90 100
100
120
140
160
2 Minutes Welding 8 Minutes Resting
4-6. Generator Power Curve
220 581
The ac generator power curves
show the generator power available
in amperes at the receptacles.
AMPERES
0
0
10 20 30 40 50 60 70 80
50
100
150
200
250
300
240 Volt
120 Volt
VOLTS