Portable Generator User Manual

OM-4417 Page 23
SECTION 8 MAINTENANCE
Follow the storage procedure in the engine owner’s manual if the unit will not be
used for an extended period.
NOTE
8-1. Routine Maintenance
Stop engine before maintaining.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
= Check = Change = Clean = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
Section 5-4,
5-5
Fuel Level Oil Level Oil, Fuel Spills
Every
25
Hours
Section 8-2
Air Cleaner Precleaner
Every
50
Hours
Weld Terminals
Every
100
Hours
Engine
Manual,
Section 8-2
Oil  Air Cleaner Element Cooling System Spark Plug Gap
Battery Terminals (DX
Models)
 Spark Arrestor Screen
(Optional on DX Models)
Every
200
Hours
Unreadable Labels
Every
300
Hours
Engine
Manual
Valve Clearance*
Every
500
Hours
Engine
Manual
 Weld Cables  Slip Rings*
 Brushes*
Every
1000
Hours
OR
Inside Unit