SECTION 6 – TROUBLESHOOTING
6-1. Troubleshooting Tables
A. Welding
.
See Sections 6-2 and 6-3 for test
points and values and Section 10
for
parts location.
Trouble Remedy
No weld output.
Check fuse F1, and replace if necessary (see Section 8-6).
Check integrated rectifier SR2, and replace if necessary
.
Check diode D4, and replace if necessary
.
Clean slip rings, and install new brushes if necessary (see Section 6-15).
Disconnect leads 21, 23, and 33 from brushes, and check continuity across slip rings. Replace rotor
if necessary.
Check resistance and connections of resistors R2 and R4; R2 and R4 are each 12 ohms
±10%.
Re
-
place resistor(s) if necessary
. Adjust R2 and R4 according to Section 6-16.
Check
resistance and connections of Fine Amperage Control
R1; R1 is 0 to 30 ohms
±
10%. Replace
R1
if necessary (see Section 3-1).
Disconnect
leads 22 and 29 from SCR/integrated rectifier SR2, and check for continuity between leads
22
and 29. Replace exciter stator if necessary
.
For
units with optional remote control, check capacitor C5 for a short or open, and check for proper con
-
nections. Replace C5 if necessary.
Check voltage regulator board PC2 and connections, and replace if necessary (see Section 6-9).
No or erratic weld output.
Clean and tighten weld connections both inside and outside unit.
Check engine speed, and adjust if necessary (see Section 8-5).
Check
to make sure Ampere Ranges switch S5 is not between positions. Check continuity of S5, and
replace if necessary.
Check
reactor AC-Z for signs of winding failure. Check continuity across windings, and check for proper
connections. Replace AC-Z if necessary.
Check
resistance and connections of Fine Amperage control R1; R1 is 0 to 30 ohms
±
10%. Replace
R1 if necessary.
Disconnect leads 21, 23, and 33 from brushes, and check continuity across slip rings. Replace rotor
if necessary.
No or erratic DC weld output only
.
Check modular main rectifier SR1, and replace if necessary
.
Check stabilizer DC-Z for signs of winding failure. Check continuity across windings, and check for
proper connections. Replace DC-Z if necessary.
Low or high weld output.
Check engine speed, and adjust if necessary (see Section 8-5).
Adjust resistor R4 slider until 128 to 132 volts ac is obtained at 100 Hz receptacle RC4 (see Section
6-16).
Adjust
resistor R2 slider until proper open-circuit-voltage is obtained at
weld output terminals (see Sec
-
tion
6-16).
Check
resistance
and connections of resistor R3 on suppressor R3, VR1 module; R3 is 1000 ohms
±
10%.
Replace R3, VR1 module if necessary
.
Check
reactor AC-Z for signs of winding failure. Check continuity across windings, and check for proper
connections. Replace AC-Z if necessary.