User guide
TM-428 Page 29
Miller Legend
6-13.
Optional Remote Capacitor Board PC5 T
esting Information Effective W
ith Serial No.
KD346698
Ref. ST-800 698-A / SA-156 026-C
Be sure plugs are secure before
testing. See Section 6-14 for spe-
cific
values during testing.
1
Capacitor Board PC5
2
Remote 14 Receptacle RC1
3 Receptacle RC2
4T
erminal K
T
est Equipment Needed:
43
1
2
6-14. Optional Remote Capacitor Board PC5 Test Point Values Effective With Serial No.
KD346698
PC5 Voltage Readings
a) Tolerance –
±10% unless
specified
b) Reference
– to circuit com
-
mon
(lead 33) unless noted
Receptacle Pin Value
RC1 A Contact
closure to pin B completes the dc contactor control circuit
B
+15 volts dc output
C
Command reference, +4.5 volts dc output
D
Remote control circuit command
E
Input command signal from potentiometer wiper
, 0 to +4.5 volts dc input
K
Chassis ground (lead 33)
RC2 1
Remote control circuit common
2
Command reference, +4.5 volts dc input
3
+15 volts dc input
4
Command signal from potentiometer wiper
, 0 to +4.5 volts dc output
5
Not used
6
Contact closure to pin 3 completes contactor control circuit
Terminal K
Chassis ground (lead 33)