Instructions / Assembly

20
Pre-Start Check List
Verify the polarity of the connections are correct, the
line voltage power leads are securely connected and
the furnace is properly grounded.
Verify the thermostat wires (R & W) are securely
connected in the burner compartment.
Verify the gas line service pressure does not exceed
10.0 inches of W.C., and is not less than 4.5 inches W.C.
for natural gas. For LP gas the line service pressure
must not exceed 14 in. W.C., and must not be less than
11.0 in. W.C.
Verify the roll-out and manual reset switch is closed. If
necessary, press the red button to reset a switch. DO
NOT install a jumper wire across a switch to defeat
its function. If a switch reopens on startup, DO NOT
reset the switch without identifying and correcting the
fault condition.
Verify the blower door is in place, closing the door switch
in the line voltage circuit.
Verify the gas line has been purged and all connections
are leak free.
Operating Instructions for PG Direct Ignition
Burner
Do not perform these steps until all of the safety checks
have been completed:
1. STOP! Read all safety information on this page.
2. Set the thermostat to OFF or to its lowest setting.
3. Turn off all electric power to the appliance. NOTE: This
appliance is equipped with an ignition device which
automatically lights the burner. DO NOT try to light
the burner by hand.
4. Turn the latch and open the furnace door.
5. Push in the gas control knob and turn to OFF.
IMPORTANT: DO NOT FORCE. Wait 10 minutes
to clear out any gas. If you still smell gas, STOP!
and read WHAT TO DO IF YOU SMELL GAS. If you
don’t smell gas, go to the next step.
6. Turn the gas control knog to ON.
7. Close the furnace door and turn the latch.
8. Turn on all electric power to the appliance.
9. Turn the thermostat to ON and set to the desired
setting.
10. If the appliance will not operate after one re-try, follow
the instructions Shutting Off the Gas Supply below
and call your service technician or gas supplier.
Shutting Off the Gas Supply
1. Set the thermostat to OFF or to its lowest setting.
2. Turn off all electric power to the appliance if service
is to be performed.
3. Turn the latch and open the furnace door.
4. Push in the gas control knob and move to OFF. DO
NOT FORCE.
5. Close the furnace door and turn the latch.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury or property
damage.
• Installation and service must be performed
by a qualifi ed installer, service agency or
the gas supplier.
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fi re department.
WARNING:
START-UP & ADJUSTMENTS
Important Safety Information
WARNING:
All safety information must be followed during
the start-up and operation of the furnace.
Unqualifi ed individuals should not attempt to
interpret these instructions. Improper servicing
could result in dangerous operation, property
damage, personal injury or death.
This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burner.
Do not try to light the burner by hand.
BEFORE LIGHTING OR OPERATING smell all around
the appliance area for gas. Be sure to smell next to the
oor because some gas is heavier than air and will
settle on the fl oor.
Use only your hand to push in and move the gas
control lever. Never use tools. If the lever will not push
in by hand, don’t try to repair it, call a qualifi ed service
technician. Force or attempted repair may result in a
re or explosion.
Should overheating occur, or the gas supply fail to shut
off, turn the manual gas valve to the appliance OFF.