Specifications

OM-2242 Page 8
1 Welding Power Source
Shoulder Strap
Install strap as shown.
Use strap to lift unit.
2 Rating Label
Label is located on bottom of unit.
Use rating label to determine
input power needs.
3 Input Power Cord
4 115 or 230 VAC Grounded
Receptacle
The Auto-Line circuitry in this
unit automatically links the
power source to the primary
voltage being applied, either
115 or 230 VAC.
An individual branch circuit capa-
ble of carrying 30 amperes and
protected by fuses or circuit
breaker is recommended. Rec-
ommended fuse or circuit break-
er size is 30 amperes.
Unit is supplied with a 115
VAC plug (CE models are
not supplied with a line
cord plug). For 230 VAC
operation, have a qualified
person obtain a proper
plug that meets all applica-
ble codes, and install the
plug according to the
manufacturers instruc-
tions.
Connect input power plug to a
proper receptacle.
Special installation may be
required where gasoline or
volatile liquids are present
see NEC Article 511 or
CEC Section 20.
Ref. 803 351-C / 208 651-D
3
3-4. Installing Shoulder Strap, Selecting A Location, And Connecting Input Power
18 in
(460 mm)
18 in (460 mm)
Airflow Distance
Requirements
2
Do not move or operate unit
where it could tip.
1
Front Panel
To Rear Panel
4
Protected By One Or More Of The
Following US. Patents:
3-5. Selecting Extension Cord (Use Shortest Cord Possible)
Single Phase AC
Conductor Size − AWG [mm
2
]*
Single Phase AC
Input Voltage
4 [21.2] 6 [13.3] 8 [8.4] 10 [5.3] 12 [3.3]
Input Voltage
Maximum Allowable Cord Length in ft (m)
115 160 (49) 107 (33) 71 (22) 47 (14) 29 (9)
230 471 (144) 321 (98) 215 (66) 146 (45) 90 (27)
*Conductor size is based on maximum 3% voltage drop