Owner`s manual

. A complete Parts List is available at www.MillerWelds.com
OM-254 170 Page 12
General
Operating Temperature 5 to 104 F (15 to 40 C)
IP Code Degree of protection provided by
enclosure
IP23CS**
IP International Protection
2 No ingress of foreign objects 12.5 mm (0.5
in.)
3 No harmful ingress spraying water
C AC line circuits protected against ingress of
tool 2.5 mm dia x 100 mm long (0.1 in. x 4 in.)
S Fan stationary during water test
**This equipment is designed for outdoor use. It may be stored, but is not intended to be used outside during precipitation unless sheltered.
Toppling or tilting Up to 15 incline
Machine Weight 21 lb (9.5 kg) including 12 ft (3.7 m) torch
23 lb (10.4 kg) including 20 ft (6.1 m) torch
Torch The XT40 torch is intended for handheld use only. The torch conforms to IEC 60974-7 when used with the Spectrum 625
X-TREME. Do not use this torch in combination with any other machines.
Gas Type Air or Nitrogen
−− −−
Gas Quality
Clean, moisturefree,
oilfree
−− −−
Gas Inlet Flow and Pressure 6.0 SCFM (170 L/min)
90 PSI (621 kPa)
Min
120 PSI (827
kPa) Max
Gas Filtering Particulates to 5 microns
−− −−
Mild Steel capacities (see Section 5-2 for cutting speeds vs material type and thickness)
Cooling Method Air
−− −−
Duty Cycle of Torch 100% at 40 Amps
−− −−
Rating of Electrical Controls (Trigger) 30 VDC at .1 Amps
Rating of Electrical Controls (Cup) 30 VDC at 1 Amp
Approved Systems Spectrum 625 X-TREME w/XT40 torch
Trigger Protection Safety trigger guard
Safety Devices Safety interlock devices shut down power source
Rated Capacity (edge start) 5/8 in. at 13 ipm (330 mm/min)*
−− −−
Sever Cut Capacity (edge start) 7/8 in. at 4 ipm (102 mm/min)*
−− −−
Pierce Capacity 5/16 in.
−− −−
*Travel speeds are approximately 80% of maximum.
Requirements for the torch connection
S Use only compressed air which is free from dirt, oil, and water.
S Ensure that the connections are properly assigned and tighened.
S For torch replacement, see Miller torch manual Part No. OM-254449
S Ensure correct air pressure (flow pressure) and airflow (volume) are set. Insufficient airflow can lead to the torch overheating.
4-2. Torch Dimensions And Weight
Ref. 253 554-A
2.2 lb (1.0 kg)
1-3/16 in.
(30 mm)
8-3/4 in.
(222 mm)
1-1/2 in.
(38 mm)