Owner`s manual
. A complete Parts List is available at www.MillerWelds.com
OM-254 170 Page 14
4-5. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the bottom. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-6. Selecting A Location
loc_2 3/96 - Ref. ST-151 556 / Ref. 804 503-A
1 Line Disconnect Device
Locate unit near correct input
power supply.
Locate unit at least 18 in. (460 mm)
away from a wall or other
obstruction to allow adequate
clearance for cooling air flow.
! Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Location
1
18 in.
(460 mm)
18 in.
(460 mm)
! Do not move or operate
unit where it could tip.
4-7. Connecting Gas/Air Supply
Ref. 805 326-A
. Use only clean, dry air with 90
to 120 psi (621 to 827 kPa)
pressure.
1 Gas/Air Inlet Opening
2 Hose
3 Teflon Tape
Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.
Tools Needed:
9/16 in.
3
From Gas/Air
Supply
1
2