Operating and Maintenance Manual Simplicity™ Water Purification System MILLIPORE Page 1/36 Operating and Maintenance Manual Simplicity™ Water Purification System MILLIPORE Page 1/36 Operating and Maintenance Manual Simplicity™ Water Purification System MILLIPORE Page 1/36
NOTICE ___________________________________________ Information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore Corporation assumes no responsibility for any errors that may appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual.
___________________________ DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY EUROPEAN UNION EC DIRECTIVES Directive 89/336/CEE Directive 73/23/CEE ◆ ◆ These Lab Water Systems are designed and manufactured in application of the following European Council directives : – 89/336/CEE relating to Electromagnetic compatibility – 73/23/CEE relating to electrical equipment designed for use within certain voltage limits Standards to which conformity is declared as applicable are the following : – EN 55022-
TABLE OF CONTENTS _____________________________________ GETTING STARTED HOW TO USE THIS MANUAL ............................................................... 6 Warnings ............................................................................................................ 6 Illustrations .......................................................................................................... 6 INTRODUCTION ..................................................................................
_____________________________________ TABLE OF CONTENTS MORE ABOUT SIMPLICITY USE OF THE KEYPAD ......................................................................... 17 Standard menu .................................................................................................. Consumable lifetime ........................................................................................... Choosing the non-temperature compensated resistivity display ..............................
HOW TO USE THIS MANUAL ______________________________ This manual describes how to install, maintain and use the Simplicity. It is recommended that this document is completely read before plugging in the unit to a source of electrical power. The system is easy to use and to maintain. However, it is wise to be familiar with all its functions as described in this manual.
_________________________________________ INTRODUCTION General Information ______________________________________ Simplicity is a water purification system fed through an integrated vented storage reservoir. The system 5 provides the final “polish” to remove any remaining contaminants in water pretreated by reverse osmosis, electrodeionization (Elix), distillation or deionization. The Simplicity system is designed to produce water of Type 1 quality.
INTRODUCTION _________________________________________ System performance Purified water quality Simplicity Simplicity 185 Resistivity TOC* 18.2 MΩ-cm at 25 °C 15 ppb 18.2 MΩ-cm at 25 °C 5 ppb Micro-organisms ≤ 1 cfu/ml ≤ 1 cfu/ml Particles (0.22 µm) < 1 / ml < 1 / ml Up to 0.5 L/mn 48 dB A at 1 metre 0.5 L/mn 48 dB A at 1 metre Flowrates Typical product water flowrate Sound level * Test conditions: System was equipped with a SimPak 1 purification Pack.
_________________________________________ INTRODUCTION Environmental Specifications Storage temperature Operating temperature Feed water temperature Altitude range -40°C to 70°C at 5% to 80% RH 5°C to 35°C at 5% to 80% RH 5°C to 30°C at 5% to 80% RH 2000 meters This equipment is designed to be used in installation/overvoltage category II and pollution degree II.
INTRODUCTION _________________________________________ Dimensions and weight Height Length Depth Weight of dry system in his box Operating weight with full reservoir Space required to remove and install the reservoir. 460 mm (18.11 inches) 248 mm (9.76 inches) 345 mm (13.58 inches) Simplicity: 5.7 Kg (12.7 lbs) Simplicity 185: 6.3 Kg (14.0 lbs) Simplicity:10.4 Kg (23.1 lbs) Simplicity 185: 11.1 Kg (24.6 lbs) 20 cm around the unit (0.
___________________________________________ INSTALLATION Unpacking ______________________________________________ After unpacking the shipping container you should find (Figure 2): Present? Yes No (A) Simplicity water purification system with reservoir (B) User manual (C) Point-of-use valve hose barb connector for purging a new SimPak Ordered separately (D) SimPak purification pack (E) Reservoir vent filter (F) SimFilter Selecting a site for the Simplicity system _____________________ Warning: Do not plu
INSTALLATION ___________________________________________ Filling the Integral Reservoir _______________________________ Figure 3 1. 2. 3. Raise the reservoir-locking handle to vertical position. (A) Pull out the reservoir (B) using the locking handle. Remove the reservoir cap (C) by twisting counter-clockwise 1/4 turn. 4. Fill the reservoir, re-install it and secure the locking handle into the body of the system. Installing the Reservoir Vent Filter ___________________________ 1. 2.
___________________________________________ INSTALLATION Electrical connection ______________________________________ The electrical wall outlet must be accessible in the event that the Simplicity must be unplugged quickly. To turn off the Simplicity, remove the power cord from the wall outlet. The AC plug is the main disconnect for the system. 1. 2. 3. Connect the power cord to a grounded power source. If necessary, put the system in STANDBY mode by depressing the OPERATE/STANDBY button for two seconds.
INSTALLATION ___________________________________________ Purging the Pak __________________________________________ 1. Install the connector (Figure 2,C) into the POU valve. Note: 2. 3. 4. 5. 6. Do not use Teflon tap on the connector tread. The seat of the valve contains an O-ring seal. The part should turn easily. Do not force, otherwise the valve thread could be damaged. Position a container under the outlet fitting. Move the dispensing valve button down to open the valve.
__________________ STANDARD OPERATING OF THE SIMPLICITY The simplicity system should be used in the manner specified by this user’s manual, otherwise the protection provided by this equipment may be impaired. Maintaining a minimum level of water in the reservoir _________ The simplicity is fed through the reservoir located at the back of the unit. Whenever the water in the reservoir reaches half a liter level it is recommended to refill it. If the simplicity runs out of water, proceed as follows: 1. 2. 3.
STANDARD OPERATING OF THE SIMPLICITY __________________ These different modes are displayed on the screen, and are described below: OPERATING MODE DISPLAY STATUS OF SYSTEM STANDBY While in this mode, the system is not producing purified water. Periodic recirculation is performed. OPERATE PROD:18.2 MΩ.cm System is running. Purified water can be delivered by opening the dispensing valve.
_____________________________________ USE OF THE KEYPAD The keypad allows the user to activate the different operating modes and to review information about consumables lifetime and system configuration.
USE OF THE KEYPAD ______________________________________ Consumable lifetime ______________________________________ KEYPAD ACTION DISPLAY PAK LIFETIME 0PERATE DISPLAY MENU In either OPERATE or STANDBY mode, press MENU for at least 2 seconds PACK AGE 45 DAYS (The pak must be replaced after a maximum 365 days in service) UV LAMP USE (only Simplicity 185) 0PERATE DISPLAY MENU UV LAMP 9 Press MENU once more to display the UV lamp age.
_____________________________________ USE OF THE KEYPAD Choosing the non-temperature compensated resistivity display __ KEYPAD 0PERATE DISPLAY ACTION MENU PACK AGE In either OPERATE or STANDBY mode, press MENU for at least 2 seconds 0PERATE DISPLAY MENU MENU Press DISPLAY once to select Temperature correction OFF. 0PERATE DISPLAY 45 DAYS TEMP.CORRECTION Press MENU button until it displays. 0PERATE DISPLAY DISPLAY MENU To accept and go back to normal operating mode, press MENU button for 2 sec.
USE OF THE KEYPAD ______________________________________ Selecting the unit of measure ______________________________ KEYPAD 0PERATE DISPLAY 0PERATE DISPLAY MENU MENU ACTION In either OPERATE or STANDBY mode Press MENU for at least 2 seconds. Press several times MENU to display. DISPLAY PACK AGE 45 DAYS PRODUCTION UNIT MΩ . cm 0PERATE DISPLAY MENU Press DISPLAY once to select MΩ.cm (resistivity) or µS/cm (conductivity).
_____________________________________ USE OF THE KEYPAD Setting the displayed language _____________________________ KEYPAD 0PERATE DISPLAY 0PERATE DISPLAY 0PERATE DISPLAY 0PERATE DISPLAY MENU MENU MENU ACTION In either OPERATE or STANDBY mode Press MENU for at least 2 seconds.
MAINTENANCE __________________________________________ Replacing the consumables ________________________________ 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Put the Simplicity into STANDBY mode by pressing the OPERATE button. Do not turn off the electrical power to the system. Remove the old SimFilter ( Figure 5,B) from the Point of Use valve. Open the Point Of Use valve for a few seconds to depressurize the system. Swing the Pack locking handle (Figure 4,E) to the left by pressing on the locking tab (4,A).
_________________________________________ MAINTENANCE 18. 19. 20. Press the OPERATE button to go from STANDBY to OPERATE mode Open the POU valve and draw around 0.5 litre of water through the SimFilter. Switch the unit to STANDBY mode. The SimFilter should be changed whenever the product flowrate becomes too low (< 0.3 Litres/mn) or whenever the SimPak is replaced.
MAINTENANCE __________________________________________ WARNING: 5. 6. Verify that there is no electrical power going to the Pack at this time. Accidental exposure to Ultraviolet light can cause damage to the eyes and skin. Push the UV lamp clip to the left and remove it (Figure 6,A). The UV lamp can now be removed from the housing (Figure 6,B). Using the new UV Lamp, follow steps 1-5 in reverse order. Note: Use the gloves to avoid getting fingerprints on the new UV lamp.
_________________________________________ MAINTENANCE Shutting down the system for an extended period of time ______ Keep the Simplicity in STANDBY mode when water is not needed for a few days. In this mode, the unit will operate all cycles to keep the water quality optimum. If the Simplicity is to be shut down for a long time, drain the reservoir, remove the SimPak and Simfilter, and unplug the system. Upon start-up, new cartridges should be installed.
TROUBLESHOOTING ______________________________________ Troubleshooting table _____________________________________ Whenever the Yellow SERVICE LED is blinking, a message is displayed on the screen, which indicates the nature of the service needed. STATUS / PROBLEM There is no electrical power to the system. CAUSE REMEDY - No electrical power. Check the source of power. - The power cord is not plugged Check the power cord. into the wall. The Simplicity system is in - The tank is empty.
_____________________________________ TROUBLESHOOTING STATUS / PROBLEM CAUSE REMEDY EXCHANGE PACK. The operational lifetime of the purification Pack has expired. Change the purification pack. PACK OUT The Pak has not been installed properly or has been removed. Put the Pack back in place. EXCHANGE UV LAMP The operational lifetime of the UV lamp has expired. Replace the UV lamp CHECK UV LAMP Defective UV lamp Occurs when the UV lamp doesn’t light anymore.
ORDERING INFORMATION ________________________________ Systems Simplicity Water Purification System, Simplicity Water Purification System, 230 V 50 Hz 115 V 60 Hz SIMS50000 SIMS60000 Simplicity 185 Water Purification System, Simplicity 185 Water Purification System, 230 V 50 Hz 115 V 60 Hz SIMS5V000 SIMS6V000 Consumables SimPak 1 Kit, for Distilled, RO or Elix feed (Includes SimPak 1, SimFilter and Vent Filter) SimPak 2 Kit, for DI feed (Includes SimPak 2, SimFilter and Vent Filter) SimPak 1 purificati
________________________________ ORDERING INFORMATION Millipore’s Standard Warranty _____________________________ Millipore Corporation (“Millipore”) warrants the products will meet their applicable published specifications when used in accordance with the applicable instructions for a period of one year from shipment of the products. MILLIPORE MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED. THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
ILLUSTRATIONS __________________________________________ Figure 1 The water flow schematic of the Simplicity is shown below. Only the main components are shown. 1 3 4 2 5 6 7 8 Reservoir Pump * UV Lamp Pak Resistivity cell Point of use with dispensing valve Check valve Final filter 1 2 3 4 5 6 7 8 * Only present on Simplicity 185. Page 30/36 ILLUSTRATIONS __________________________________________ Figure 1 The water flow schematic of the Simplicity is shown below.
__________________________________________ ILLUSTRATIONS Figure 2 A B MAN UAL MILLI MILLIPORE POR E D C E F Page 31/36 __________________________________________ ILLUSTRATIONS Figure 2 A B MAN UAL MMILLI ILLIPPORE ORE D C E F Page 31/36 __________________________________________ ILLUSTRATIONS Figure 2 A B MAN UAL MILLI POR E D C E F Page 31/36
ILLUSTRATIONS __________________________________________ Figure 3 A B D C Page 32/36 ILLUSTRATIONS __________________________________________ Figure 3 A B D C Page 32/36 ILLUSTRATIONS __________________________________________ Figure 3 A B D C Page 32/36
__________________________________________ ILLUSTRATIONS Figure 4 E A B C D Page 33/36 __________________________________________ ILLUSTRATIONS Figure 4 E A B C D Page 33/36 __________________________________________ ILLUSTRATIONS Figure 4 E A B C D Page 33/36
ILLUSTRATIONS __________________________________________ Figure 5 A B Page 34/36 ILLUSTRATIONS __________________________________________ Figure 5 A B Page 34/36 ILLUSTRATIONS __________________________________________ Figure 5 A B Page 34/36
__________________________________________ ILLUSTRATIONS Figure 6 A B Page 35/36 __________________________________________ ILLUSTRATIONS Figure 6 A B Page 35/36 __________________________________________ ILLUSTRATIONS Figure 6 A B Page 35/36
To Place an Order or Receive Technical Assistance For additional information call the nearest number listed below: In the U.S. and Canada, call toll-free 1-800-MILLIPORE (1-800-645-5476) In the U.S., Canada and Puerto Rico, fax orders toll-free 1-800-MILLIFX (1-800-645-5439) On the Internet http://www.millipore.com E-mail: tech_service@millipore.com Millipore Worldwide AUSTRALIA Tel. 1 800 222 111 or (02) 9888 8999 Fax (02) 9878 0788 AUSTRIA, CENTRAL EUROPE, C.I.S., AFRICA, MIDDLE EAST AND GULF Tel.