System information

APPENDIX
the floppy disk and the floppy path changed to save files to the sub-directory. This
allows full use of the disk space.
316 Not enough storage to create a new file
There is not enough parts space to create a new conversational program. Erase
unnecessary programs to free up parts space.
317 Simulator allows only 15 events
319 Send file aborted
320 Invalid PLC program.
One of the ACRO.HEX (or NCB.HEX) files in the RAM directory is corrupt.
402 Y axis software limit overtravel
When jogging or handwheeling and an axis limit is reached, the control will only
allow movement in one direction.
In a program the error may be encountered. The G92 and/or G54 parameters may
need to be modified.
Tool length offsets are also a potential cause of Z axis overtravel.
321 Error in program O.
A custom MCODE or customer GCODE has an error.
322 or custom G code program not found.
323 or custom M code program not found.
324 Invalid path or program not found for M6 tool change macro.
The tool change macro may have an error in it.
400 Home required
The machine must be homed before any axis movement can take place on the
machine, i.e. MDI, JOG, HDW, etc.
401 X axis software limit overtravel
403 Z axis software limit overtravel
404 A axis software limit overtravel
405 B axis software limit overtravel
406 C axis software limit overtravel
These errors are a result of the axis reaching the programmed limits of travel.
410