System information
APPENDIX
407 X axis excess error condition
411 B axis excess error condition
Is the program in block mode or feedhold?
408 Y axis excess error condition
409 Z axis excess error condition
410 A axis excess error condition
412 C axis excess error condition
These errors are caused by the axis not being able to keep up with the
programmed move at the programmed speed.
Does the error occur during rapid moves only? Y__ N__
If so, check bus voltage and rapid feed parameters.
Do any of the drive cards have red LED's lit? Y__ N__
If so, which light on which card? VOL, GF, RMS, or SG
Other causes might be too heavy of a cut, worn tool, low ∀15 volts, accel/decel
parameters, or drive card failure.
413 Attempted to move into safe zone
415 Can't establish DNC link while program is running
The program being run must be halted before the DNC link can be established.
416 Out of position, arc end point is not on the arc
417 Can't edit parameters while program is running
The program must be halted before editing parameters.
418 Controller Card Error
448 Air Pressure Error. Check air hose connection
449 ERROR 449: Emergency stop: Axis drive fault. Reset servo drives or power
down.
450 ERROR 450: Emergency stop condition. Reset drives or press <ESC> to clear
this message.
451 Lube fault, Check Waylube Level
The float switch on the autolube pump is indicating that oil needs to be added to
the autolube tank.
452 Tool not found in auto tool sequence
Check UTIL-TLCHG-SLOTS for that tool number.
411