System information
APPENDIX
605 Can't modify dry run status while program is running
Program must be halted before changing dry run status.
Try HALT-DRY-RESUME.
606 Program N#### is empty
Text program being run or verified is empty. Try editing and reposting the
conversational file.
607 Can't exit DNC run mode while program is running
The DNC mode must be halted before exiting.
608 'P' expected in M98 block
609 G20/21 not allowed in DNC Fast
610 Position move required after this rotation
611 Feed must be specified in every block while inverse time mode is active.
666 Quill movement detected, reposition the quill to it's original position.
Digitizing Errors
800 Illegal probe block
Syntax error in guidance file. Check the block format. Blocks must start with an
X, Y, or Z which is to be followed by one or two P commands.
801 Missing end of pick
Pick boundary is not closed. Input file did not end with a pick boundary definition
block.
802 Reversed scan segment
Multiple scan segment started that would cause the scan direction to change in the
middle of the current scan.
803 Missing end of scan
Pick segment terminated before the end of scan was defined. There should be at
least two scan definition blocks between each pick boundary.
804 Reversed pick segment
Multiple pick segment started that would cause a change in pick direction. Use
multiple probe segments if this is the desired intention.