System information
SECTION TWO - FRONT PANEL OPERATION
During the tool setting routine, the tool table is loaded with the appropriate values. After all the
tool offsets are loaded, the operator can press ESC (Halt) to exit the tool setting routine.
Note: This routine can be modified for specific applications (auto tool setters, different tool
changers etc.).
F5 (MDI) Main-MDI
The F5 (MDI) key on the Main menu selects the MDI (manual data input) function. Through
MDI any programmable machine function can be executed one function or one block at a time.
When MDI is selected the following screen appears.
As the functions are typed in they will appear on the MDI line at the bottom of the screen. After
the data has been typed in, Enter must be pressed to end the block. At this point a Cycle Start
will execute the MDI line. During MDI the ESC (Esc) key will terminate any MDI command. F6
will bring up the normal graphic displays discussed earlier. If graphics are turned on during
MDI, the graphic display will graph all the MDI moves as they are executed.
F1 (Gcode) Main-MDI-Gcode
F1 (Gcode) will bring up a list of legal G codes with a short description of each code. Pressing
the F1 (Gcode) key will bring you to the next page of G codes.
00 Linear Rapid 01 Linear Feed
02 CW Arc 03 CCW Arc
04 Dwell 09 One-Shot Exact Stop
10 Set Data Mode 11 Clear Data Mode
12 Clear Floating Zero 17 XY Plane
18 XZ or ZX Plane 19 YZ Plane
32