System information
SECTION TWO - FRONT PANEL OPERATION
Note: When editing or entering parameter values (or any other numeric value on the control),
you can use the built in calculator.
Example: Instead of entering .3750 you may enter 3/8
Instead of entering 1.3750, you may enter 1 + 3/8
If you want to modify the current value, you may use “.” as the current
value.
If the current value is .358 and you want to add .002, type .+.002 (instead
of entering .360).
The F3 key brings up the power-on defaults as shown in the following screen.
Front Panel Type: Standard or Mini-Series Membrane
FP Control Port (Cent 7): Front Panel port 1552 for standard Cent 7 systems
Video Mode: Standard settings are 640 x 350 for CRTs and 800 x 600 for LCDs
Initial Units are: G20 English or G21 Metric to power up in inch or metric.
Number of Axes: Can be 1 to 5.
Serial Keyboard : Enables or disables serial keyboard
The keyboard will boot up transmitting over the CLK/DATA interface and not over the RS-232
interface. This means the PC will be able to recognize that a keyboard is present upon reset and
not hang with a message such as, <PRESS F1 TO RESUME>. The keyboard will always
37