System information
SECTION TWO - FRONT PANEL OPERATION
Hard Tap Fudge Factor Used to adjust the depth of rigid tapping cycle. Higher
numbers will decrease the amount of overshoot at the
bottom of the hole.
Feed Back on Mitutoyo Scale Yes will enable the Z axis feedback from the Mitutoyo
scale options.
Feed Back on Quill Scale Yes enables the glass scale for Z axis quill options.
Quill Epsilon If the value is zero no error checking is done for quill
movement. If the value is none zero, quill motion is
monitored while a program is running. If the quill moves,
the control goes into block mode and an error 666 "Quill
motion detected, return the quill to it's original position –
12.3456" will be displayed. The program will not continue
until the quill is returned to it's original position. The
position of the quill at the start of a program (and during
tool changes) is saved and used to compensate Z positions
during the program.
Quill Scale Encoder The encoder to use for the glass scale for Z axis quill
options.
Quill Scale PPU The pulses per inch for the quill scale encoder.
Back Gear Reverse If the back gear input is sensed and the parameter is Yes,
the outputs for CW and CCW are reversed.
Keyboard Code 015 for systems with a CAT900 card, 0 for others
Yaskawa Drives Yes, if it has Yaskawa drives (Yaskawa drives give a drive
OK signal instead of a drive fault signal)
Door Open Switch See notes on European code (page 55) at the end of this
section.
European Code See notes on European code (page 55) at the end of this
section.
Auger Aux (Cent 7 and up) The front panel Aux buttons can be assigned to specific
functions. To assign the Aux1 button to the auger enter
Setup Aux (Cent 7 and up) "001", to assign the Aux2 button to the setup button enter
"002" in the parameter
Door Open Axis See notes on European code (page 55) at the end of this
Door Open Input section.
50