System information

SECTION TWO - FRONT PANEL OPERATION
Door Open Override Axis See notes on European code (page 55) at the end of this
Door Open Override Input section.
Check Tool Door Open If Yes, Z input 10 is checked before tool changer arm is
commanded. If the input is not seen in 15 seconds, a
timeout error is displayed.
Check Processor If Yes and the over temperature Z input 4 is
Temperature made, an over temp message will be displayed.
Cool-Down Time (Min) Used on spindle air-purge systems.
(Cent 6 and up)
Lube Cycle Time Used on spindle air-oil lubricating systems.
(Cent 6 and up)
Recycle Pump Time (Secs) Used on coolant through the spindle systems.
(Cent 6 and up)
Max Feed w/Door Open See notes on European code (page 55) at the end of this
section.
Soft Start Delay (Secs) The time delayed before allowing axis movement after the
machine is reset.
Digital Readout in E-Stop If Yes the axis position display will be updated even when
emergency-stopped.
Probe Axis and Probe Designates which axis and input number for the
Input Probe 1 and Probe 2 commands to use.
Cranking Minutes/Rev How many minutes of normal program execution time
correspond to one turn of the handwheel. Multiplying an
IPM feed time, this factor results in an IPR feed (inches per
turn of the handwheel). This parameter should be
approximately 0.0010 for our current systems.
Cranking Factor Multiplier for each handwheel click is approximately 100
for our current systems. Cranking/Factor/Cranking
MinsPerRev is proportional to the max feedrate allowed
while hand-cranking.
Cranking Max IPM This limits the feedrate while hand-cranking to get
reasonable response at slow programmed feedrates.
Adjusting the other parameters can give excess errors on
51