System information
SECTION TWO - FRONT PANEL OPERATION
Only tools 1 through 25 are monitored and will have these parameters available. The spindle load
bar will also have a number associated with it.
Serial Port Data
Note: Com port, baud rate, parity, data bits and stop bits are communications parameters. See
page 100, Section 4 on F4 (RS232) for more information.
Primary Serial Port NONE, COM1, or COM2
COM1 Baud Rate 110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200
COM1 Parity, Data N/7/1, N/7/2, N/8/1, N/8/2, E/7/1,
and Stop Bits E/7/2, E/8/1, E/8/2, O/7/1, O/7/2, O/8/1 or O/8/2
COM2 Baud Rate 110, 150, 300, 600, 1200, 2400, 4800, 9600 or 19200
COM2 Parity, Data N/7/1, N/7/2, N/8/1, N/8/2, E/7/1,
and Stop Bits E/7/2, E/8/1, E/8/2, O/7/1, O/7/2, O/8/1 or O/8/2
Secondary Serial Port NONE, COM1, or COM2
Tape Start Character ASCII value used to send when opening a com port
Tape Stop Character ASCII value used to send when closing a com port
RS232 Buffer Size 1 for users not doing long RS-232 communications, up to
255 to improve RS-232 in DNC
LF in change to CR Yes means change all carriage returns received on RS-232
to line feeds
End of Block Send Yes means send a carriage return/line feed at the
CR/LF end of blocks sent out on the RS-232
RS232 EOF Character ASCII value of character sent at end file sent on RS-232
71