Installation manual

Chapter 1. Commissioning
PELLERIN MILNOR CORPORATION
Figure 7: Rear-mounted Water Inlet Assembly (C_E Models)
Figure Legend
.
1.
Cold water inlet
2.
Vacuum breaker
3.
Water outlet into shell
4.
Hot water inlet
Notice 17 :
Pellerin Milnor Corporation accepts absolutely no responsibility for damage
to its equipment or to any textiles therein when concentrated chemicals dribble out of the
injection tubes onto any part of the machine or its contents.
— End of BIWUUI01 —
BICEUI01 (Published) Book specs- Dates: 20040120 / 20040120 / 20040120 Lang: ENG01 Applic: CEX
1.4. Electrical Connections for Liquid Chemical Systems
WARNING 18 : Electric Shock Hazard
—Contact with high voltage electricity will kill or
seriously injure you. Even when the machine is not running, three-phase power and control
circuit power are still present at several locations within the cabinet and at some electrical
components.
CAUTION 19 : Injury and Damage Hazards
—Improper wiring can cause the machine to
malfunction, risking injury to personnel, damage to machine components, and damage to goods.
Electrical and piping connections described in this section must be made only by
qualified, authorized personnel.
Lock off and tag out power at the external disconnect switches for the washer-extractor
before proceeding.
Do not rely merely on the information in this section when wiring. Consult all applicable
electrical schematics.
Do not reroute or rearrange any wires not specifically permitted by this instruction.
Do not connect a common wire to ground. Use the common terminal furnished.