Installation manual

Chapter 2. Programming
PELLERIN MILNOR CORPORATION
Figure 5: Location of DIP Switches
Processor Board Legend
A. DIP switch
B. Board identification area
1. OFF
2. ON
3. ON
4. OFF
DIP Switch (Partial View)
.
Table 5: DIP Switch Settings for Industry Configurations
Switch Settings
Industry Configuration
S1
S2
S3
S4
S5
S6
S7
S8
Correctional Facilities
ON
ON
ON
ON
Hotels and Motels
OFF
ON
ON
ON
Athletic Laundries
ON
OFF
ON
ON
Healthcare Facilities
OFF
OFF
ON
ON
Restaurants
ON
ON
OFF
ON
Commercial Laundries
OFF
ON
OFF
ON
Shirt Laundries
ON
OFF
OFF
ON
Offshore Laundries
OFF
OFF
OFF
ON
This switch is
not used in
these models.
On
prevents/Off
allows
skipping
steps.*
These switches
are not used in
these models.
Fire-Fighter
ON
ON
ON
OFF
* Setting S6 off enables the operator to cancel any step in progress except a drain before an extract.
— End of BICJHC02 —
BICJHP02 (Published) Book specs- Dates: 20070828 / 20070828 / 20070828 Lang: ENG01 Applic: CJH CJV MXU
2.3. Programming the E-P Plus
®
Controller
The microprocessor controller used in this washer extractor operates in three modes, depending on
whether the machine is processing goods (the Run mode or Formula menu), being programmed
with operating characteristics to be used when a wash formula is started (the Program mode), or
being tested (the Manual or Test mode). This document describes the available operator actions and
display feedback in the Program mode.
The Program mode is accessible only when the Run/Program keyswitch is set to the Program
position (
P
), as described below. From the Program menu, there are four options available:
Option 0: OK TURN KEY TO RUN (detailed in Section 2.3.2)
Option 1: ADD/CHANGE FORMULA (detailed in Section 2.3.3)
Option 2: CONFIGURE (detailed in Section 2.3.4)
Option 3: STANDARD FORMULAS