Installation manual

Chapter 5. Supplemental Information
PELLERIN MILNOR CORPORATION
5.1.9. Pressure Sensor
The 188 E-P Plus
®
processor board contains a pressure transducer unit mounted directly to the
board. This transducer produces a very small voltage (about 0.1 millivolt per inch of water) that
increases as the water level in the basket rises. Refer to “Testing the Level Transducer” in “The E-P
Plus
®
Manual Menu.”
— End of BICJUF01 —
BICUDC01 (Published) Book specs- Dates: 20070828 / 20070828 / 20070828 Lang: ENG01 Applic: CJH CJV MXU
5.2. Serial Memory Storage Device Applications
A serial memory storage device similar to one shown below can be used to store machine
configuration and formula data for most current models of Milnor
®
machines. DIP switches inside
the storage device allow you to configure the device to accept data from several different machine
types and software versions. Use this document to determine the proper DIP switch setting for your
machine. After verifying the switch settings, label the storage device with the date, machine name,
and serial number to avoid confusion when the device is needed to restore data to a machine.
Figure 10: Serial Memory Storage Device