User Manual

Chapter 4
Installation Instructions
4.1 General
The
Speed HPTx
is installed by a professional technician. Several possibilities for
installation have been programmed into the system in order to provide solutions for
installation of various types of water meters. The
Speed HPTx
installation is
performed using a stainless steel clamp that enables connection to pipelines of
different diameters (0.75", 1.00", 1.50" or 2.00").
The
Speed HPTx
unit is protected so that it is impossible to open or dismantle the
box without breaking the four one-time screw locks.
4.2 Installation
For on-site installation of the
Speed HPTx
device, proceed as follows:
1) Loosen the four screws fastening the unit's box and open the box cover.
2) Install the unit's box base as required:
a. For pipeline installations (as in Figure 2-1), first attach the stainless steel
clamp (see Figure 4-1) to the pipeline, close it around the pipeline and
fasten the screw in the middle of the device. Place the unit's box base on
top of the screw and install it using two steel screws.
b. For wall mounting of the unit, install the base directly onto the wall or
surface using the two steel screws.
3) Connect the wire pairs from the water meters to the terminal blocks on the
PCB. Up to four such pairs can be connected, with unused connections left
open (i.e., no termination is required).