Technical Characteristics
3.1 Technical Specification
3.1.1 Electrical
Max Effective Radiated Power (ERP)
60 mW
(Complies with FCC 90.205(g) )
Output frequency 450-470 MHz
Carrier wave modulation 2 Level FSK
Power supply Lithium battery, 3.6 Volt
Input Channels 1-10 Water Meters
Compatibility Any type of meter which has a
reed relay switch (pulsed
output)
Transmission Duration 0.8 Sec. Max.
Duration between Transmissions At least 10 Min.
3.1.2 Physical
Operating temperature
-30°C ÷+50°C
Water Resistance Splash resistance (IP-64)
(IP 68-optimal)