User's Manual

Chapter 4
Installation Instructions
4.1 General
The Speed Tx is installed by a professional technician. Several possibilities for
installation have been programmed into the system in order to provide solutions for
installation of various types of water meters. The Speed Tx installation is performed
using a stainless steel clamp that enables connection to pipelines of different
diameters (0.75", 1.00", 1.50" or 2.00").
The Speed Tx unit is protected so that it is impossible to open or dismantle the box
without breaking the four one-time screw locks.
4.2 Installation
For on-site installation of the Speed Tx device, proceed as follows:
1) Loosen the four screws fastening the unit's box and open the box cover.
2) Install the unit's box base as required:
a. For pipeline installations (as in Figure 2-1), first attach the stainless steel
clamp (see Figure 4-1) to the pipeline, close it around the pipeline and
fasten the screw in the middle of the device. Place the unit's box base on
top of the screw and install it using two steel screws.