Operator’s Manual

16 M12 160x120 Thermal Imager Operator’s Manual
Figure 10. Live Visual Camera View
Press
again to return to the thermal image view.
Using the Built-In Visual Image Camera
Every time you take a thermal picture, the Thermal Imager
captures a visual image at the same time. When you save
a thermal image, the Thermal Imager saves the visual
image that goes with it as well. Just like with thermal
images, you can see live visual images on the display.
Press the button to switch between thermal and visual
images.
Figure 10 shows a visual image as it would appear on
the display. This is the companion to the thermal image in
Figure 8. There is no temperature data associated with a
visual image. Visual images are to help you identify objects
in thermal images.
The visual image camera has its own lens. It is xed-focus.
(No focus adjustment is necessary.) The visual image
camera lens is a small rectangular window below the lens,
forward of and above the trigger.
NOTE
If visual images ever seem to have poor quality,
check to see if this lens is dirty. Clean it gently
with a camera lens tissue moistened with camera
lens cleaner uid.