Operator’s Manual

M12 160x120 Thermal Imager Operator's Manual 15
230
138.9˚F
95
CANCEL
SAVE
Figure 9. SAVE or CANCEL a New Image
7. To write the image to SD card, press the button
on the arrow keypad or pull the trigger again. Or, to
discard the image, press the arrow button to highlight
CANCEL, then press the button.
NOTE
Every minute, the Thermal Imager pauses to
calibrate its thermal sensor. You will hear clicking
sounds. This is normal behavior. The Thermal
Imager does not respond to button presses during
calibration pauses.
LOW BATTERY
LOW BATTERY
In the live thermal image in Figure 8, the 120.0 °F
reading at the top of the display is the temperature
inside the center target. The bottom of the display
shows the color palette over the temperature span
(in this case, 86 °F to 122 °F). Span is adjusted
automatically in auto-range mode (default setting). This
manual explains how to use manual range settings
under “Optimizing Thermal Images.”
122
120.6˚F
86
MANUALAUTO
Figure 8. Live Thermal Image
6. When the display shows the object or scene framed
the way you want it, pull the trigger to take a thermal
picture. The display then presents you with choices to
SAVE or CANCEL the new image. See Figure 9.