Operator's Manual S/N L03A

33
2 M18™ WIRELESS MONITOR
CAMERA LIGHT
2019/10/23 01:47:57 AM 9.3FT
2019_10_23_SCREEN
LINE TRACE
OFF 33kHz 83kHz
The LINE TRACE is now active, and the LINE TRACE icon with selected frequency will
appear in the status bar.
CAMERA LIGHT
2019/10/23 01:47:57 AM 9.3FT
2019_10_23_SCREEN
LINE TRACE
33kHZ
3. Deactivate the LINE TRACE mode by turning the navigation dial to LINE TRACE ,
press the navigation dial and select OFF, and press.
2.3.9 SONDE
SONDE - activates the SONDE transmitter attached at the end of the PIPELINE
INSPECTION REEL termination spring to locate the approximate position of the SONDE
in the pipe. The choice of the SONDE frequency was selected during setup and can
be changed by going to SETTINGS, and then SONDE FREQUENCY. The choices of
SONDE frequencies to use are 33kHz, 512Hz or 640Hz.
33kHz – is useable in non-metallic pipes.
512Hz – is mostly used in North America and is useable in both metallic and non-metallic
pipes
640Hz – is mostly used in Europe and is useable in both metallic and non-metallic pipes