Use and Care Manual

4 5
READ AND SAVE ALL
INSTRUCTIONS FOR FUTURE USE
FUNCTIONAL DESCRIPTION
1. Vacuum Port
2. Side Handle Clamp Attachment Point
3. Tool and Bit Adjustment Button
4. Depth Gauge
5. Depth Gauge Button
6. Nozzle
7. Nozzle Assembly
8. Bit Brush
9. Side Handle Clamping Collar Assembly
10. Clamp Lever
11. Side Handle Grip
SPECIFICATIONS
Cat.
No.
Vacuum Port
Diameter
Max. Bit
Diameter
For use with Hammer Collar Sizes
Diameter / Circumference
5261-DE 2-1/2"
1-7/8"
1-1/2"
1-1/4"
5/8" S = Ø 43-46 mm (1.7"-1.8") / 135-144.5 mm (5.3"-5.7")
M = Ø 48-55 mm (1.9"-2.2") / 151-173 mm (6"-6.9")
L = Ø 56-59 mm (2.2"-2.3") / 176-185 mm (6.9"-7.2")
ASSEMBLY
Connecting the Vacuum Hose
Attach the vacuum hose to the port. Twist to form
a tight t.
Installing/Removing Nozzle Assembly
To install the nozzle assembly supplied with the
tool, or accessory nozzles:
1. With the nozzle assembly
pointing straight up, line
up the lugs of the nozzle
assembly with the lugs on
the front of the HAMMER-
VAC™. The unlock symbol
on the nozzle assembly
will line up with the mark on
the top of the HAMMER-
VAC™.
2. Turn the nozzle assembly
left or right to lock into place.
The lock symbol on the
nozzle assembly will line up
with the mark on the top of
the HAMMERVAC™.
3. To remove, reverse the pro-
cedure.
Installing/Removing Nozzle
Replace the nozzle:
After drilling about 1500 holes,
• When the bit brush shows signs
of wear,
When suction is reduced,
• When dust escapes through the
bit brush during use
To replace the nozzle (Cat. No.
49-90-2301), press in the release
button and pull out from the lower
nozzle assembly. Slide the new
nozzle into the lower nozzle as-
sembly until it snaps into place.
Attaching the HAMMERVAC™ to a Rotary
Hammer/Hammer Drill
The HAMMERVAC™ is provided with three clamp-
ing collar assemblies and one side handle grip.
Choose the correct clamping collar assembly for
the tool being used (see Speci cations). The side
handle grip should be unscrewed from one as-
sembly to be used on another.
1. Disconnect power from the tool.
2. Remove the tool side handle.
3. Partially screw side handle grip onto clamping
collar assembly
4. Slide the HAMMER-
VAC™ side handle
clamping collar assem-
bly over the chuck and
onto the neck of the tool.
The clamp lever must be
facing up (3).
5. Attach the side handle
clamping collar assem-
bly onto the HAMMER-
VAC™, first the upper
jaw, then lower jaw.
6. Press down the clamp
lever (3) to secure the clamping collar assembly
to the HAMMERVAC™.
7. Rotate the HAMMERVAC™ and side handle
grip to the desired position, and tighten securely.
Adjusting the Side Handle Position
1. Loosen the side handle clamping collar assembly
by unscrewing the side handle grip until the side
handle clamping collar assembly rotates freely.
2. Rotate the side handle grip to the desired posi-
tion.
3. Tighten the side handle grip securely.
Installing/Removing the Bit
Slide the bit through the nozzle and then install
into the tool according to the tool manufacturer's
instructions.
Fitting the HAMMERVAC™
to the Tool and Bit
For proper suction and depth
control, position the nozzle as-
sembly so the bit is ush with
the forward face of the nozzle:
1. Slide the clamping collar
forward or backward to ac-
commodate the length of
the bit. Press the clamping
lever down to tighten se-
curely.
2. Press and hold the tool and
bit adjustment button.
3. Push in the nozzle assem-
bly until the bit is ush with
the front face of the nozzle.
4. Release the tool and bit ad-
justment button.
NOTE: Fully extend the HAMMERVAC™ before
storing to preserve spring life.
Setting the Drilling Depth
1. Fit the HAMMERVAC™ to the Tool and Bit.
2. Press and hold the depth gauge button and
slide the depth gauge to the desired depth. The
drilling depth is the last visible measurement
shown when viewed from the top of the tool.
To ensure the HAMMERVAC™ is properly set
to the tool, bit, and desired depth, always drill
a test hole.
Drill Depth
Correct
Incorrect
Incorrect
WARNING To reduce the risk of injury,
always use side handle provided with dust
extractor when using with a rotary hammer/
hammer drill. When dust extractor is removed
from the tool, always use side handle(s) sup-
plied with the tool. Loss of control can cause
personal injury.
11
9
8
10
6
7
5
4
1
3
2
1
3
2