Operating instructions

J
B3
.
CHECK/ADJUST
MAGNIFIER
GAIN
AND
REGISTRATION
(R430,R445)
a
.
Set
the
time-mark
generator
for
0
.1-millisecond
markers
.
b
.
Set the
MAG
switch
to
X10
and
set
the
POSITION
controls
to
midrange
.
Set
the
mainframe
intensity
controls
for
the
desired
display
.
c
.
Check
for
1
marker/division
over
the
center
8
divisions
of
display
(position
as
necessary)
.
d
.
ADJUST---13430
(Mag
Gain)
for
1
marker/division
over
the
center
8
divisions
of
display
.
e
.
Set the
time-mark
generator
for
0
.5-millisecond
markers
.
Align
the
center
time
marker
with
graticule
center
.
J
f
.
CHECK----Set
the
MAG
switch
to
X1
and
check
that
the
center
time
marker
is
at
graticule
center
within
0
.5
division
.
g
.
ADJUST-----13445
(Mag
Reg)
to
align
the
center
time
marker
with
graticule
center
.
h
.
INTERACTION---Set
the
MAG
switch
to
X10
and
repeat
parts
e,
f,
and
g
as
necessary
.
J
B4
.
CHECK
VARIABLE
TIME/DIVISION
AND
VARIABLE
HOLD
OFF
a
.
Press
and
release
the
VARIABLE
TIME/DIV
control
for
uncalibrated
sweep
rates
.
Set the
VARIABLE
control
fully
clockwise
and
note 3 time
markers
in
10
graticule divisions
.
J
b
.
CHECK---Set
the
VARIABLE
control
fully
counter-
clockwise
and
check
for
2
divisions
or
less
between
5-
millisecond
markers
.
c
.
Press the
VARIABLE
control
in
for
calibrated
sweep
rates
.
d
.
Set the
LEVEL
control
for
a
free-running
display
(TRIG'D
light
off)
.
e
.
Set the
HOLD
OFF
control
fully
counterclockwise
.
V
f
.
CHECK----Rotate
the
HOLD
OFF
control
slowly
clockwise
throughout
its
range
and
check
that
the
display
(3
time
markers
in
10
divisions)
will
stabalize
at
least
3 times
throughout
the
range
of
the
HOLD
OFF
control
(disregard
any
slow
drift)
.
g
.
Set
the
HOLD
OFF
control
counterclockwise
to
MIN
and
set
the
LEVEL
control
for
a
stable
display
.
J
PerformanceRequirement
check
;
see
introductory
information
.
Performance
Check
and
Adjustment---71387
B5
.
ADJUST
50
ns
SWEEP
TIMING
(C330)
a
.
Set the
TIME/DIV
switch
to
50
ns
and
set
the time
mark
generator
for
50-nanosecond
markers
.
b
.
Check
for
1
marker/division
over
the
center
8
divisions
of
display
(position
as
necessary)
.
c
.
ADJUST---C330
(50 ns Timing)
for
1
marker/
division
over
the
center
8
divisions
of
display
(position
as
necessary)
.
V
B6
.
CHECK
INTERNAL
CLOCK
FREQUENCY
RANGES
a
.
Set
the
71381
TIME/DIV
switch
to
10
,us
.
b
.
Connect
the
frequency
counter
I
IX probe
tip
to
TP673
and
the
ground
lead to
the
GND
test
point
.
V
c
.
CHECK
----That
the
clock
frequency
is
10.240
MHz,
within
the
limits
of
10
.230
to
10
.250
MHz
.
Check
that
the
repetition
rate
output
for
each
TIME/DIV
switch
setting
is
approximately the
same
as
that
shown
in
Table 5-2
.
d
.
Set the
AQS
CLOCK/AQR
switch
to
I
NT
=
1000,
the
TIME/DIV
switch
to
50
ors,
and
the
MAG
switch
to
X1
(in)
.
TIME/DIV
TABLE
5-2
Acquire Clock
Repetition
Rate
Output
MAG
X10
(Button
Out)
5
ms
~~~
10
ms
20
ms
__
50
ms
.1
s
.5
s
1
s
-------
-
--------
2
s
5_S
MAG
X1
.1
ms
2
ms
5
ms
1
ms
2
.048
MHz
20
.48
MHz
T
1`
.024^M-Hz
~
10
.24
MHz
_L
.
.
.
.m-
._
.-_----------
512
.0
kHz
2
04
.8
kHz
102
.4
kHz
5
.12
MHz
-------------
2.048
MHz
1
.024
MHz
'
_^vW
5-
1 1
51
.2
kHz
20
.48
kHz
0
.24Hz
-k-__
.__ .__
-------
512
.0
~kHz
__
_
.__
.
.~
204
.8
kHz
_-'
102-
.4
-_
kHz
_
5
.12
. .
.
kHz
_
. . .
.
.
_-
.
5
_
1
_
.2
_
._kHz
_
2
.048
kHz
20
.48 kHz-
.
.
_
__ ._
1
-
.024
kHz
-__
. .
.__
.
._
10
.24
W
kHz
512
.0
Hz
--5
.12
.--------
_
.
_
.
kHz
W
204
8
-
.
Hz
2
.048
kHz
-
11
__
102
.4
Hz
1
.024
kHz
512H?
512
.0
Hz
_
-_
.
20
:
48
_
.H?-
T
._
._
._
.-
.
.__
._
_
.
._
.
.---------
__-
204
.8
Hz