Repair Instructions S/N J08A

19
E.2
Change power cord
4
Disassemble the handle, top cover, filter and hatch back as described in previous Section E.0.
Disconnect the wires on power cord from their connection points on switch and earth grounding
(fig.1-3).
Unscrew the cable relief (use TX10 bit) and pull the cord out of the relief hole (fig.4).
Install new power cord of same type as original.
Then repeat the process backwards to assemble the machine. Be carefull to place the cord in
the proper cable guides.
1
2
3
WARNING: The upper section of the
machine contains live components.
Contact with live components leads
to serious or even fatal injuries.
Always disconnect the mains plug
before disassembly.