Specifications
CHAPTER 4 Daily Maintenance Before executing the [PUMP TUBE WASH]
4-20
4 At this point, either of [FILLING UP] and [DISCHARGE] can be selected by pressing
the [] or [] key.
5 Press the [ENTER] key to go to the lower level of hierarchy and supply the cleaning
solution.
Once the cartridge is installed, the supply of the cleaning liquid will start.
Cleaning liquid is drawn up and the tubes are filled with the cleaning liquid.
Go to step 6 when the cleaning liquid is to be supplied for the first time or to step 8 when it is to be supplied
after the discharge of the old cleaning liquid.
6 Set a filling liquid cartridge according to the instruction on the display.
7 The cleaning solution is supplied.
Either of the following displays will appear if a problem with the filling liquid
cartridge is detected.
MaintWashLiquid
DISCHARGE <ent>
MaintWashLiquid
FILLING UP <ent>
To step 5 To step 10
Remove a filling
up cartridge.
There is a CARTRIDGE
Remove a wash liquid
cartridge.
There is a CARTRIDGE
Supply for the first time Supply after discharge
Set a filling up
cartridge.
CARTRIDGE : none
Remove a wash liquid
cartridge.
There is a CARTRIDGE
Set a filling up
cartridge.
CARTRIDGE : END
Set a filling up
cartridge.
CARTRIDGE : WRONG
FILLING UP NOW.
PLEASE WAIT
∗ ∗ ∗ ∗ ∗ ∗ ∗ − − − − − − − − − − −