Specifications
4-33
CHAPTER 4 Daily Maintenance Setting periodical operations in stand-by mode [ROUTINE SETUP]
Setting periodical operations in stand-by mode [ROUTINE
SETUP]
While the printer is waiting for the next printing job, it can perform various operations at fixed intervals to
prevent ink clogging or the like.
The [ROUTINE SETUP] function is available for the following items:
Preventing ink condensation on the nozzle face [ROUTINE WIPING]
With the temperature of the print heater having been set high or use of a larger amount of ink (high concen-
tration, two-layer application, etc.) having been set, “ink splaying”, “ink drops falling”, or “nozzle miss-
ing” may occur.
The cause of these phenomena is such that the ink of the print is heated by the print heater immediately
after printing and resultantly evaporated solvent may condense on the nozzle face.
The greater the difference between the setting temperature of the print heater and the ambient temperature
is, the more easily ink can condense.
This function wipes the condensed ink off the nozzle face at intervals during printing.
STEPS:
1 Make sure that the printer is in LOCAL mode, and then select [MAINTENANCE] using
the [FUNCTION] key and press the [ENTER] key.
If it is in REMOTE mode, press the [REMOTE] key.
2 Select [ROUTINE SETUP] by pressing the [] key six times and press the [ENTER]
key.
3 Press the [ENTER] key.
Once [SCAN COUNT] is displayed, press the [ENTER] key.
ROUTINE WIPING
During printing, the printer performs nozzle face wiping at fixed intervals to remove con-
densation. [SCAN COUNT] and [TEMP.difference] can be set.
REFRESH Set the interval at which refreshing operation is to be performed periodically.
TUBE WASH Set the interval at which cleaning of the pump tubes is to be performed periodically.
CLEANING
Set the cleaning type and the interval at which cleaning operation is to be performed peri-
odically.
PRE PRT AFT
35°C 40°C 50°C
L. ∗ > [JV5-01]
width : ∗∗∗∗ mm
PRE PRT AFT
35°C 40°C 50°C
FUNCTION
MAINTENANCE <ENT>
MAINTENANCE
ST.MAINTENANCE <ent>
MAINTENANCE
ROUTINE SETUP <ent>
6
times
Wiping in the
drawing is set up.
ROUTINE SETUP
ROUTINE WIPING <ent>
The interval of
wiping is set up.
ROUTINE WIPING
SCAN COUNT <ent>