Specifications
Table Of Contents
- TABLE OF CONTENTS
- CAUTION
- Foreword
- For safe operation
- How to Read This Operation Manual
- CHAPTER 1 Before Use
- CHAPTER 2 Basic Operations
- CHAPTER 3 Useful Function
- Changing origin
- Adjusting head gap
- When nozzles missing can not be improved
- Setting the print condition in a set
- Setting the print condition
- Setting media compensation
- Setting the print method
- Registering head gap value
- Set the scan width of the head
- Changing the UV illumination intensity
- Sets UV irradiation at starting/ ending of drawing
- Setting the priority
- Sets the cooling time per scan
- Initializing the settings
- Turning OFF the UV lamp
- Setting the UV lamp OFF duration
- Changing the UV illumination intensity
- MACHINE SETUP
- Other useful functions
- CHAPTER 4 How to care
- Maintaining
- Ink cartridge
- Washing cartridge
- Cleaning the flushing box
- Avoiding ink dripping at printing
- When the waste ink tray is full
- Setting nozzle face cleaning time
- Perform cleaning automatically when the power supply is turned on
- Preventing nozzle dropout while power-off
- Regular maintenance of white ink
- If blur or missing remains
- Wiper cleaning
- Refill antifreeze liquid
- Cleaning of the UV lamp filter
- Cleaning of the UV power supply filter
- Cleaning of the optional vacuum unit filter
- Replacing the mist fan filter
- Replacing UV lamp
- Checking method of UV illumination intensity
- Cleaning of the Ionizer
- Prevent the nozzle clogging of spot color
- CHAPTER 5 In Case of Trouble
- CHAPTER 6 Appendix

4-28
Refill antifreeze liquid
Supply antifreeze liquid and water to the hot water tank in the water
heating device that runs for keeping the ink at an appropriate tem-
perature. Check the device every month.
Precautions for refilling
Precautions in handling the antifreeze liquid
• Water and antifreeze liquid compound ratio should be 2(water) to 1(Antifreeze liquid).
• When only water is supplied to the hot water tank without antifreeze liquid, it may damage the
head.
• When only antifreeze liquid is supplied to the hot water tank without water, the liquid tempera-
ture does not increase, and may cause an error.
• Check the water is on the required level in the water heating device every month.
• If water in the water heating device frequently becomes insufficient, contact a distributor in
your district or our office.
• Dispose of the waste water mixed with antifreeze liquid pursuant to the regulations of your
district.
• Be sure to wear goggles and gloves for handling the antifreeze liquid.
• Use the recommended antifreeze liquid by Mimaki. If not, the water heating device may be
broken. (Supplied antifreeze liquid : SPC-0394 [1000cc x 2 bottles])
• Do not touch the antifreeze liquid directly. If the antifreeze liquid settles on the skin or clothes,
immediately wash it off with soap and water. If you get antifreeze liquid in your eyes,
immediately wash your eyes with a lot of clean water. Then, consult a doctor as soon as
possible.
• Store antifreeze liquid in a dark and cold place.
• Store antifreeze liquid in a place that is out of the reach of children.
• When discarding antifreeze liquid which is no longer needed, entrust them to an industrial
waste disposal contractor, clarifying their contents.
• Before using antifreeze liquid, be sure to read the Material Safety Data Sheet (MSDS).
• When purchasing a spare hot water tank, contact a distributor in your district or our office.
• Prepare a tank with a cap to put in the waste water from hot water tank.
• When water in the hot water tank is low, an error message is
displayed. In this case, replace water in the same way shown
as the next page.
Water heating
device
WA T E R L A C K