Specifications
Table Of Contents
- TABLE OF CONTENTS
- CAUTION
- Foreword
- For safe operation
- How to Read This Operation Manual
- CHAPTER 1 Before Use
- CHAPTER 2 Basic Operations
- CHAPTER 3 Useful Function
- Changing origin
- Adjusting head gap
- When nozzles missing can not be improved
- Setting the print condition in a set
- Setting the print condition
- Setting media compensation
- Setting the print method
- Registering head gap value
- Set the scan width of the head
- Changing the UV illumination intensity
- Sets UV irradiation at starting/ ending of drawing
- Setting the priority
- Sets the cooling time per scan
- Initializing the settings
- Turning OFF the UV lamp
- Setting the UV lamp OFF duration
- Changing the UV illumination intensity
- MACHINE SETUP
- Other useful functions
- CHAPTER 4 How to care
- Maintaining
- Ink cartridge
- Washing cartridge
- Cleaning the flushing box
- Avoiding ink dripping at printing
- When the waste ink tray is full
- Setting nozzle face cleaning time
- Perform cleaning automatically when the power supply is turned on
- Preventing nozzle dropout while power-off
- Regular maintenance of white ink
- If blur or missing remains
- Wiper cleaning
- Refill antifreeze liquid
- Cleaning of the UV lamp filter
- Cleaning of the UV power supply filter
- Cleaning of the optional vacuum unit filter
- Replacing the mist fan filter
- Replacing UV lamp
- Checking method of UV illumination intensity
- Cleaning of the Ionizer
- Prevent the nozzle clogging of spot color
- CHAPTER 5 In Case of Trouble
- CHAPTER 6 Appendix

Changing origin
3-3
3
Useful Function
Changing origin with FUNCTION menu
To precisely set the origin of coordinates, set its X- and Y- coordinates from the FUNCTION menu. This
setting value becomes the origin position (0, 0).
1
Press the key in the local
mode.
2
Select the [ORIGIN] by pressing the
or key, and press the
key twice.
• X-axis offset value setting screen is displayed.
3
Input value by pressing the
or keys, and press the
key.
• Setting the origin position of X-axis.
• The value in the parentheses indicates the distance from the origin to the maximum
effective area.
4
Select the [Y OFFS] by pressing the
or keys, and press the
key.
5
Input value by pressing the or
keys, and press the key.
• Setting the origin position of Y-axis.
• The value on the first line indicates the distance from the origin to the maximum effective
range.
6
Press the key several times to end the setting.
• The set value remains even if turning off the power.
<LOCAL>
FUNCTION
FUNCT I ON
OR I G I N < ENT >
ENTER
OR I G I N ( 5 9 0mm )
XOFFSET : 10mm
ENTER
OR I G I N
YOFFSET <ent>
ENTER
OR I G I N ( 5 5 0mm )
YOFFSET : 150mm
ENTER
END