Specifications
Table Of Contents
- TABLE OF CONTENTS
- CAUTION
- Foreword
- For safe operation
- How to Read This Operation Manual
- CHAPTER 1 Before Use
- CHAPTER 2 Basic Operations
- CHAPTER 3 Useful Function
- Changing origin
- Adjusting head gap
- When nozzles missing can not be improved
- Setting the print condition in a set
- Setting the print condition
- Setting media compensation
- Setting the print method
- Registering head gap value
- Set the scan width of the head
- Changing the UV illumination intensity
- Sets UV irradiation at starting/ ending of drawing
- Setting the priority
- Sets the cooling time per scan
- Initializing the settings
- Turning OFF the UV lamp
- Setting the UV lamp OFF duration
- Changing the UV illumination intensity
- MACHINE SETUP
- Other useful functions
- CHAPTER 4 How to care
- Maintaining
- Ink cartridge
- Washing cartridge
- Cleaning the flushing box
- Avoiding ink dripping at printing
- When the waste ink tray is full
- Setting nozzle face cleaning time
- Perform cleaning automatically when the power supply is turned on
- Preventing nozzle dropout while power-off
- Regular maintenance of white ink
- If blur or missing remains
- Wiper cleaning
- Refill antifreeze liquid
- Cleaning of the UV lamp filter
- Cleaning of the UV power supply filter
- Cleaning of the optional vacuum unit filter
- Replacing the mist fan filter
- Replacing UV lamp
- Checking method of UV illumination intensity
- Cleaning of the Ionizer
- Prevent the nozzle clogging of spot color
- CHAPTER 5 In Case of Trouble
- CHAPTER 6 Appendix

When nozzles missing can not be improved
3-8
Reset the set value
Supported from the firmware ver.1.90.
1
When <LOCAL> is displayed, press the
key.
2
Select the [MAINTENANCE] by
pressing the or key, and
press the key.
3
Select the [NOZZLE RCVR] by pressing
the or key, and press the
key.
4
Select the [INIT] by pressing the
key.
5
Select the Nozzle line that needs clear
the setting value by pressing or
key.
•Press the key, the contents set for all nozzle lines are deleted.
6
Press the key.
7
Press the key several times to end the setting.
<LOCAL>
FUNCTION
FUNCT I ON
MA I NT ENANCE < ENT >
ENTER
MA I NT ENANCE
NOZ Z L E RCVR < ENT >
ENTER
NOZ Z L E RCVR
INIT< >DRAW
NOZ Z L E RCVR
CLEAR : NOZZLE 1 ( K )
DATA CLEAR
ENTER
END